![chromasens 3DPIXA Manual Download Page 45](http://html1.mh-extra.com/html/chromasens/3dpixa/3dpixa_manual_2605699045.webp)
5 Installing the 3D scanner system
3DPIXA
CD40131 Version 1
45 / 99
5.5.2
Connecting the camera
1. Connect the camera via CameraLink cables to the frame grabber:
Fig. 21: Connecting the camera to the frame grabber
1
CameraLink Port 1 (base mode)
2
CameraLink Port 2 (additionally required for medium mode)
3
Master/Slave synchronization
– Connect CL1 of the 3DPIXA camera to the first port of the frame grabber (1).
– If the camera will be operated in medium mode, connect CL2 of the 3DPIXA camera
to the second port of the frame grabber (2).
– 3DPIXA dual: Synchronize the master and slave via the I/O ports (3).
For the pin assignment of the master/slave synchronization cable, refer to
chapter 10.2.1, p. 95.