![chromasens 3DPIXA Manual Download Page 16](http://html1.mh-extra.com/html/chromasens/3dpixa/3dpixa_manual_2605699016.webp)
2 Technical data
16 / 99
CD40131 Version 1
3DPIXA
2.6.2
GPUs
If the CS-3D-Viewer V2.3 and the CS-3D-API are used, CUDA 3.0 capable GPU is required.
The calculation speed of the 3D data depends on the GPU used for the 3DPIXA application.
Chromasens regularly tests GPUs for their compatibility with the 3DPIXA cameras. A list
of GPUs tested can be found on our partner portal at http://www.chromasens.de/user
(Downloads > System Requirements > 3DPIXA System Requirements).
2.7
Ambient conditions
General ambient conditions
Life phase
Standard
Operation
IEC 721-3-3:IE33
Transport
IEC 721-3-1:IE11
Storage
IEC 721-3-2:IE21
Tab. 9: General ambient conditions
Camera-specific ambient conditions
Condition
Value
Temperature during camera operation
0 °C to 60 °C, 32 °F to 140 °F (housing
temperature)
Air humidity during camera operation
20 to 85% relative air humidity,
noncondensing
Storage/transport temperature
–20 to +85 °C, –4 °F to 185 °F
Protection category
IP50
Tab. 10: Camera-specific ambient conditions