
- 24 -
© 2014 Chromalox
®
, Inc.
1-888-996-9258
5
Specifications
Control Inputs
Accepts all of the following as standards:
On/Off Control
Signal Input
120 thru 230 Vac ± 10%
5-32 Vdc
Contact Closures
Proportional Control
Signal Input
Input Impedance
4 - 20 mA
.................
250 Ohms
1 - 5 Vdc
..................
10k Ohms or greater
0 - 5 Vdc
..................
10k Ohms or greater
0 - 10 Vdc
................
10k Ohms or greater
Optional Remote Manual Adjust
Auto/Manual Switch
Instrument Power
......
120 or 230 Vac
50/60 Hz
Output Voltage
...........
0 - 99% RMS line voltage
(Eo=Vsupply - 1.5V SCR
forward drop)
Resolution (proportional) Better than 0.1%
Line Voltage
...................
120 - 575 Vac, 60 Hz
CE 400 Vac 50 Hz
Load Current Rating
......
100, 150, 200, 300, 400,
550, 650, 800, 1000, 1200A
Ambient Temperature
....
0 - 50°C (32 - 122°F)
SCR Capability
Dielectric
.................
Withstand capability
Surge Rating
1500V RMS min.
Typically fifteen (15) times
nominal RMS rating for
8.3 milliseconds
Isolation
.....................
SCRs isolation 2500V
Input-output isolation 1500V
Heat Sink
........................
Ground potential up to
650 Amps
High Temperature
..........
AC Voltage Output
Indicator Output
100 mA @ Instrument Power
Shorted SCR
..................
AC Voltage Output
Indicator Output
100 mA @ Instrument Power
MaxPac I, II, and III
MaxPac IP
Control Inputs
Accepts all of the following as standards:
Phase Angle Control
Signal Input
Input Impedance
1 - 5, 0 - 5mA
..........
1K Ohms
4 - 20, 0 - 20mA
......
250 Ohms
10 - 50, 0 - 50mA
....
100 Ohms
Optional Remote Manual Adjust
Fan Power
.................. 120 or 230 VAC
50/60 Hz
Output Voltage
........... 0 - 99% RMS line voltage
(Eo=Vsupply - 1.5V SCR
forward drop)
Resolution (proportional) Better than 0.1%
Line Voltage
............... 120, 208, 240, 277, 380,
......................................
480
and 575 Vac
± 10% 50/60 Hz
Load Current Rating
.. 100, 150, 200, 300, 400,
550, 650, 800, 1000, 1200A
Ambient Temperature
....0 - 50°C (32 - 122°F)
SCR Capability
...............Withstand capability
1500V RMS min.
Typically fifteen (15) times
nominal RMS rating for
8.3 milliseconds
Surge Rating
..................Typically fifteen (15) times
nominal RMS rating for
8.3 milliseconds
Isolation
..........................SCRs isolation 2500V
Input-output isolation 1500V
Heat Sink
........................Ground potential up to
650 Amps
Thermostat
.....................4 Amps @ 120V resistive
2 Amps @ 240V resistive
N.C. Contact Standard
Current Limit
..................10 - 100% of rated
output current
Soft Start
........................25% demand per second
typical reset speed
8.3 milliseconds