THERMAL FUSE INSTALLATION/REPLACEMENT (con’t.)
Model Number
Used On
F, FM, FH
Standard OTS Heater
RF, RFM, RFH
FL, FLM, FLH
L-Shaped OTS Heater
RFL, RFLM, RFLH
F Amp Capacity - 25 Amps; RF Amp Capacity - 5 Amps;
Blank (low) Temp = 180˚F; M (Medium) Temp - 230˚F; H (High) Temp = 300˚F.
(Max Process Temperature)
Medium temp. most common for this style heater.
RF sensors require additional control components which include a Relay,
Audible Alarm, and Manual Reset Pushbutton.
Specify 120 or 240 V when ordering.
Thermal Fuse Replacement Protection Devices