The kit comes complete with all necessary wiring and mount-

ing screws. A wall box plate is included for remote mounting of
the selector switch and can be discarded if the switch is to be
mounted on the heater.

To install on the heater, open the wiring access door located

on the bottom of the heater by turning the captive latching screw
90 degrees in either direction (Figure 1). The selector switch is to
be mounted using the knockout hole on the front of the heater,
located right above the Chromalox or Heatflo label (Figure 2).
The switch has all of the wiring connected to the correct terminals
with the three leads to be wired to other components marked by
their respective terminal number, these are wire numbers 2, 8 and
11. (Figure 3, Figure 3A) Before installing the switch, check all
the wiring connections to be sure none have become loose during
shipping and handling.

GENERAL

INSTALLATION

The fan switch and relay kit is used for all 480 Volt LUH/KUH
heaters, when summer fan only operation is required. See Model
Number versus Kit Model Number on page 3. This kit can also be
used where low voltage control wiring is specified.

WARNING: 

Hazard of Electric Shock. This kit must

be installed by a qualified electrician. Before per-
forming any of the following operations, disconnect
all power to the heater to prevent possible fatal
injury.

© 2010 Chromalox

®

, Inc.

Summer Fan Switch Kit With Relay

Model Number

ESFS-40
ESFS-40A
ESFS-41
ESFS-41A
ESFS-42
ESFS-42A
ESFS-47

DIVISION  

4

                                      SECTION  

LUH/KUH

SALES

REFERENCE

DATE

SERVICE REFERENCE

Installation Instructions

and

RENEWAL PARTS IDENTIFICATION

PF481-3

161-303477-002

NOVEMBER, 2008

(Supersedes PF481-2)

Figure 1

Figure 2

Captive

Latching

Screw

Summer Fan

Switch

Knockout Hole

Figure 3

Figure 3A

Selector Switch

2 Pole Relay

Wall Plate

Selector Switch

3 Pole Relay

Wall Plate

Summer Fan Switch

w/ Relay

Mounting
Hardware

Mounting
Hardware

Summary of Contents for ESFS-40

Page 1: ...ose during shipping and handling GENERAL INSTALLATION The fan switch and relay kit is used for all 480 Volt LUH KUH heaters when summer fan only operation is required See Model Number versus Kit Model Number on page 3 This kit can also be used where low voltage control wiring is specified WARNING Hazard of Electric Shock This kit must be installed by a qualified electrician Before per forming any ...

Page 2: ...n the fan circuit is first turned on check the rotation of the fan to be sure air is moving from the back of the heater to the front If the air is moving in the opposite direction inter change the motor lead connections on the bottom of the relay which should correct the air flow direction X1 X2 Motor 1Ø or 3Ø L3 L2 L1 Power 60Hz Cutout XFMR To Element Wiring Optional Disconnect Switch Built in or...

Page 3: ... ESFS 42 LUH D 10 21 34 00 ESFS 42 LUH D 10 23 34 00 ESFS 42 LUH D 10 43 32 00 ESFS 41A LUH D 12 83 34 00 ESFS 42 LUH D 12 23 34 00 ESFS 42 LUH D 12 43 32 00 ESFS 41A LUH D 15 83 34 00 ESFS 42 LUH D 15 23 34 00 ESFS 42 LUH D 15 43 32 00 ESFS 41A LUH D 20 23 34 00 ESFS 42A LUH D 20 43 32 00 ESFS 41A LUH D 25 43 32 00 ESFS 41A LUH D 30 83 34 00 ESFS 42A LUH D 30 23 34 00 ESFS 42A LUH D 30 43 32 00 E...

Page 4: ... BLVD OGDEN UT 84404 Phone 1 800 368 2493 www chromalox com Limited Warranty Please refer to the Chromalox limited warranty applicable to this product at http www chromalox com customer service policies termsofsale aspx ...

Reviews: