Chromalox CES-100 Installation, Operation And Renewal Parts Identification Download Page 4

Diagram 1

3 Phase Voltage

3 Phase Voltage

3 Phase Voltage

Boiler

208

240

480

Boiler

208

240

480

Boiler

208

240

480

WIRING

TYPICAL WIRING DIAGRAMS

WARNING:

Hazard of Electric Shock. Boiler must be

suitably grounded according to N.E.C. standard.

1.

Be sure to use the proper wire. Electric wiring to boiler should be
in accordance with National Electrical Code or local wiring code
following wiring diagram supplied. (See recommendations on
safety switches and fusing.)

2.

The unit is completely wired and pre-tested before shipment. No
internal wiring is required.
If a separate control circuit is used, the control circuit should be
connected to the control terminal block, inside access door (not
required with transformer).

3. Safety Switches —

WARNING:

Purchaser should use a

safety switch employing circuit breakers or fuses
between his main power source and the boiler.

4.

Because of their water lines, boilers are susceptible to lightning
damage. Industrial type lightning protectors should be installed per
manufacturer’s recommendations at your service entrance. Check

your contractor or electrical dealer for recommended type for your
system.

5.

Be sure all electrical connections are sufficiently tightened.

6.

WARNING:

Substitution of components or modifica-

tion of wiring system voids the warranty and may
lead to dangerous operating conditions.

7. SPECIAL INSTRUCTIONS FOR CUSTOMERS SUPPLY-

ING THEIR OWN CONDENSATE OR PUMP SYSTEMS.
A.

Check the voltage of the motor before making the wiring con-
nection. Some Chromalox boilers are supplied with dual volt-
age systems. The motor should always match the voltage of the
control circuit.

B.

The motor circuit should be wired into the pump control as
shown in wiring diagram (float type pump control). If boiler is
equipped with solid state pump control, refer to wiring diagram
and use terminals 5 and 2.

Use Applicable wiring diagrams based on model number and power voltage.

CES-6

1

1

1

CES-30

2

2

3

CES-100

8

8

9

CES-9

1

1

1

CES-36

2

2

3

CES-135

10

11

CES-12

1

1

1

CES-48

4

4

5

CES-160

12

13

CES-18

1

1

1

CES-60

6

6

7

CES-180

10

11

CES-24

2

2

3

CES-72

6

6

7

Export

14

2PS

BR

Heater

Contactors

Feed Water

Boiler On

3

GND

B
FU6

B 1PB

Off

1

GND

1

GND

1 HTR

C1

FU1

FU2

FU3

FU5

FU4

H1

H2

X1

X3

L3

1L1

1L3

1L2

L2

L1

X2

X4

Optional Transformer

1

1

C1

2

2

C4

C3

C2

R

1LT

Y

On

IFS

O

1PS

O

O

W

Feed Water

Electrical

Connection

2

1

1TB

1 2 3

3

GND

1

GND

2

GND

1

HTR

FU6

FU

1PB

Cabinet Exterior Left Side

Cabinet Exterior Right Side

Panel Layout

Wire Color Code

B

= Black

BR = Brown
R

= Red

O

= Orange

Y

= Yellow

G

= Green

BL = Blue
W = White

* Boilers under 40 Amps total (not fused)

4

Summary of Contents for CES-100

Page 1: ...3 50 6 17 CES 135 13 9 136 30 5 410 8 50 4 50 8 17 1 30 CES 160 16 1 157 5 30 5 475 7 60 3 60 7 22 5 CES 180 18 4 180 30 5 543 8 60 4 60 8 22 5 Chromalox DIVISION 4 SECTION CES SALES REFERENCE DATE SE...

Page 2: ...nection Conduit Box Element I Steam Outlet Sight Glass Element Access Door 5 8 7 16 Bolt Hole typical Drain Blowdown Valve K A B C Check Valve D H F E G Operating Pressure Control Safety Valve Outlet...

Page 3: ...ust be main tained 3 Complete all piping to boiler Connect water line to tagged fitting on the motor and pump assembly if used or to tagged fitting on water control feeder 4 When any type of feed othe...

Page 4: ...ed 6 WARNING Substitution of components or modifica tion of wiring system voids the warranty and may lead to dangerous operating conditions 7 SPECIAL INSTRUCTIONS FOR CUSTOMERS SUPPLY ING THEIR OWN CO...

Page 5: ...R C2 FU4 FU5 FU6 2L1 2L3 2L2 Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 3 2PS BR Heater Contactor Feed Water Boiler On 3 GND B FU6 B 1PB Off 1 GND 1 HTR C...

Page 6: ...3 C2 FU7 FU8 FU9 C3 3L1 1L3 3L2 3 HTR C3 Heater Contactor Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 5 2PS BR Heater Contactors Feed Water Boiler On 3 GND...

Page 7: ...C3 C4 FU 10 11 12 4 Htr FU10 FU11 FU12 C4 4L1 4L3 4L2 4 HTR C4 Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 7 2PS BR Heater Contactor Feed Water Boiler On...

Page 8: ...ND Cabinet Exterior Left Side Cabinet Exterior Right Side Panel Layout Feed Water Electrical Connection Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 9 FU 1...

Page 9: ...H1 H4 H2 H3 FU24 FU23 FU22 FU21 FU20 FU13 C8 C7 7 HTR 6 HTR 7L1 8L3 8L2 8L1 5L3 7L2 C5 C7 Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 11 FU 1 2 3 FU 4 5 6...

Page 10: ...7L2 FU FU FU C7 C6 Heater Contactor Heater Contactor Heater Contactor Heater Contactor Heater Contactor Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 13 FU...

Page 11: ...in valve or release man ual blowdown switch If low water cutout is automatic reset pump or solenoid will return water level to normal If low water cutout is manual reset then manual reset button on Mc...

Page 12: ...ustomer Supplied 2 Turn on boiler and allow pressure to build up to operating pressure 3 Only open globe valve at quarter turns at first introducing smaller amounts of steam into process Avoid opening...

Page 13: ...E CLOSED and the BOILER ON should light up again Now turn the wheel on the large timer until the OFF tab passes the TIME NOW arrow The BOILER ON light should go out and the valve should begin to open...

Page 14: ...circuit balance is achieved The slightest change in the pressure of the controlled medium will cause a change in the number of elements energized to compensate for it thus keeping the pressure constan...

Page 15: ...stage loads of the type used in Chromalox steam boilers It features progressive sequencing first on first off which equalizes the operating time of each load This control gives visual indication of e...

Page 16: ...ed 3 Connect piping from discharge to water inlet check valve on boil er with minimum of 90 bends or other restrictions 4 All electrical wiring should be done by licensed electricians in accordance wi...

Page 17: ...sure to drop to zero before ser vicing WARNING Provision should be made to prevent water damage from any eventual leaking of boiler or com ponents Install near a floor drain 2 On automatic feed units...

Page 18: ...end life 2 If generator is undersized for its application heaters will be over worked and reach end of life sooner 3 Element has been overheated due to excessive scale build up The scale acts as an i...

Page 19: ...50Hz 193 300175 002 Motor only used in ES 38020 115V 60Hz 193 300175 004 Strainer used in ES 38020 351 118664 001 V Band Mount used in ES 38002 ES 38020 355 300174 001 Solenoid Valve used in ES 38002...

Page 20: ...0 amp 600V 128 121133 066 60 amp 600V 128 121133 067 Fuse Block 35 60 amp 60 amp 600V 129 047445 002 Power Terminal Blocks 3 pole 115 amp 1 line circuit 1 load circuits 303 071809 032 3 pole 175 amp 1...