Local Operation
3-21
Connecting the / FAULT-OUT signal of TTL PIN8 on AC Source rear
panel to TTL PIN8 on A615003 rear panel as selecting HIGH VOLTAGE
item in OPTION of AC Source 61501 - 61504, thus A615003 can be
activated.
3.7.6 THREE PHASE MODE
When users need a three-phase AC power, it's allowed to assemble three AC sources to be
a three-phase AC power. The user can set 3-PHASE MODE on OUTPUT functional list
(see 3.7). The AC source setting as MASTER sends SYNchronized signal to SLAVEs to
position phase angle. The SLAVEs also use the signal to trigger and shut down the output.
To send synchronized signal, users have to use a special cable. One terminal of the cable
is connected to SYN (in rear panel, BNC connector), it’s the MASTER. Another terminals
connects to /Remote-Inhibit of TTL signal (in rear panel, 9-Pin D-Type connector, see
Appendix A), it’s the SLAVE. For more information about the cable, please consult your
dealer.
The procedure of using THREE PHASE MODE:
1. Connect the N terminals of AC source outputs. (For 3-phase, Y connection).
2. Connect the cable for synchronism.
3. Power on all AC sources. Keep all in output quit state.
4. Set the 3-PHASE MODE = MATER, DEGREE = 0. And set another AC source
3-PHASE MODE = SLAVE, DEGREE = 240 or 120. Press
PAGE/EXIT
twice to MAIN
PAGE. Set the voltage and frequency on each AC source. It is better for all AC
sources set the same frequency.
5. Press
OUT/QUIT
at MASTER to start output. Press
OUT/QUIT
again to quit the output.
OUT/QUIT
of SLAVE is no use when 3-phase mode.
To change THREE PHASE MODE from OFF to SLAVE as below:
1. Move the cursor to the command line
of “3-PHASE MODE=”.
2. Turn RPG to change the option from
OFF to SLAVE, then press
ENTER
.
3. The cursor moves to the command line
of “ DEGREE =” automatically.
4. Press
1
,
2
,
0
, then press
ENTER
.
3-PHASE MODE
=
OFF_
3-PHASE MODE = SLAVE
DEGREE = 0.0_
DEGREE = 120.0
Summary of Contents for 61501
Page 1: ...i Programmable AC Source 61501 61502 61503 61504 User s Manual ...
Page 2: ......
Page 3: ...Programmable AC Source 61501 61502 61503 61504 User s Manual Version 1 6 January 2010 ...
Page 7: ...v ...
Page 20: ......
Page 26: ......
Page 28: ...Programmable AC Source 61501 61502 61503 61504 User s Manual 3 2 ...
Page 29: ...Local Operation 3 3 Figure 3 1 ...
Page 56: ......
Page 118: ......
Page 134: ......