Status
State Value
Description
Communication Fault
Lost communication with the module
after the module has been detected.
Programming
Upgrading the photon software.
Detection Fault
Cannot establish communication with the
photon module after system start up.
Upgrade Failed
The upgrade failed.
145 VOM Board
OK
Properly detected and initialized the
device.
Unknown
Cannot determine the status of the
device.
Communication Fault
The device failed to respond or provided
a bad response to a command while the
light source is on.
The projector remains on until the AC
power is removed even if this warning
condition is fixed.
Detection Fault
Cannot read the device hardware
information.
Initialize Fault
Cannot properly initialize the device.
Communication Fault
The device failed to respond or provided
a bad response to a command while the
projector is in Standby mode.
Signal Group (SST+SIGN?)
The Signal group provides values and fault conditions relating to the video signal status for Christie
.
#
Status
State Value
Description
50
Output Frequency
N/A
No video is being displayed.
<rate>Hz
Where <rate> : the output frame rate,
in Hertz
51
Frame Locked
N/A
No video is being displayed or an
internal test pattern is being
displayed.
Locked
The output is locked to the selected
input(s).
Christie status system
Christie Technical Reference–Status System
10
020-103327-03 Rev. 1 (04-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.