![Christie SUHD983-P Technical Reference Download Page 35](http://html.mh-extra.com/html/christie/suhd983-p/suhd983-p_technical-reference_2603539035.webp)
External Control
–
ASCII Protocol
SUHD983-P LCD Panel Serial Commands Technical Reference
35
020-001766-01 Rev. 1 (01-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Result:
ALL: SHA=080
Get color temperature value.
Commands
Command (ASCII)
Description
Values
K:ALLCTT?
Get color temperature value.
0=studio1
1=studio2
2=warm
3=normal
4=cool
5=user
Examples
Get color temperature value.
K:ALLCTT?
Result:
ALL: CTT=001
Get red gain value.
Commands
Command (ASCII)
Description
Values
K:ALLRGN?
Get red gain value.
0 ~ 100
Examples
Get red gain value.
K:ALLRGN?
Result:
ALL: RGN=080
Get green gain value.
Commands
Command (ASCII)
Description
Values
K:ALLGGN?
Get green gain value.
0 ~ 100
Examples