![Christie Spyder X80 Technical Reference Download Page 80](http://html.mh-extra.com/html/christie/spyder-x80/spyder-x80_technical-reference_2603498080.webp)
Commands
X80 Serial Commands Reference
80
020-102207-08 Rev. 1 (10-2020)
Copyright
©
2020 Christie Digital Systems USA Inc. All rights reserved.
RCS–Request Connection Status
Allows for the current connected or disconnected status of a specified input to be queried.
When called, the system polls the current connector type of the specified input in an attempt to
determine if a video source is connected. Do not call this command too frequently (more than once per
second) as system performance may degrade.
Syntax
RCS <LayerID>
Response
<Result Code> <Layer ID> <Current Connector Type> <Connection Status>
page
for additional information on Result Codes
.
Arguments
Argument
Description
Values
<LayerID>
Sets the ID of the layer to check the connection status on.
—
Returned values
Response
Values
Connection status
0 = Disconnected
1 = Connected
2 = Unknown
Current connector type
0 = HDMI
1 = Display Port
2 = SDI