5-2
Solaria One/Solaria One
+
Service Manual
020-101039-02 Rev. 1 (06-2013)
Section 5: Troubleshooting
DMD Over-temperature Warning
• Tap
Menu
>
Status
and then
Temperatures
in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, turn the lamp off and allow the cooling fans to cool the projector.
• Check the condition of the air filters and clean or replace them if they appear to be dirty.
• Verify that all fans are operating.
5.2
Lamp Functionality
Lamp Does Not Ignite
• Tap
Menu
>
Advanced Setup
>
Lamp History
and verify the number of hours the lamp has operated.
Replace a lamp nearing the end of its operational life.
• Tap
Menu
>
Status
and then
Interlocks
in the left pane. Check and correct all interlock failures.
• Tap
Menu
>
Status
and then
All Alarms
in the left pane. If a ballast communication error has occurred,
restart the projector and turn the lamp on.
• Tap
Menu
>
Status
and then
Temperatures
in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, turn the lamp off and allow the cooling fans to cool the projector. Ensure the
projector is properly ventilated and the air filters are not blocked.
• Listen for a clicking noise that indicates the ballast is attempting to strike the lamp. If you do not hear a click-
ing noise, there might be a problem with the ballast. Contact a Christie accredited service technician to
resolve the issue.
• If you hear a brief clicking noise, but the lamp does not ignite, replace the lamp.
Lamp Suddenly Turns Off
• Tap
Menu
>
Advanced Setup
>
Lamp Power/LiteLOC Setup
. Increase the lamp power.
• Tap
Menu
>
Status
and then
Interlocks
in the left pane. Review and correct all interlock failures.
• Tap
Menu
>
Status
and then
Temperatures
in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, turn the lamp off and allow the cooling fans to cool the projector. Ensure the
projector is properly ventilated and the air filters are not blocked.
• Replace the lamp.
LiteLOC
™
Not Working
• Tap
Menu
>
Advanced
Setup
>
LampPower/LiteLOC™ Setup.
Tap
Enable LiteLOC
™
.
• If the lamp power is at the maximum setting to maintain a LiteLOC™ setting, LiteLOC™ is automatically
disabled. Reduce the LiteLOC™ setting, or install a new lamp.
5.3
Display Issues
No Image Appears
• Make sure the lamp is on.
• Make sure the douser is open.
• Make sure a white test pattern is selected.
• Make sure the service doors are closed.
• Verify the marriage icon on the main window of the touch panel controller (TPC) is green.
Summary of Contents for Solaria One
Page 1: ...Solaria One Solaria One S e r v i c e M a n u a l 020 101039 02 ...
Page 2: ......
Page 3: ...Solaria One Solaria One S e r v i c e M a n u a l 020 101039 02 ...
Page 8: ......
Page 28: ......
Page 70: ......
Page 76: ......
Page 80: ......
Page 87: ......