![Christie Secure II Series Technical Reference Download Page 60](http://html1.mh-extra.com/html/christie/secure-ii-series/secure-ii-series_technical-reference_2603534060.webp)
External control
–
HEX protocol
Secure Series II LCD Panels Technical Reference
60
020-001915-01 Rev. 1 (03-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
Command (hex)
Description
Values
07 01 01 53 45 52 08
Reads the serial number (13 Bytes)
—
Read the serial number:
07 01 01 53 45 52 08
Result:
07 01 00 53 45 52 53 55 48 44 39 38 56 34 35 30 30 30 33 08
S U H D 9 8 V 4 5 0 0 0 3
Reads the model name.
Command (hex)
Description
Values
07 01 01 4D 4E 41 08
Reads the model name (13 Bytes)
—
Read the serial number:
07 01 01 4D 4E 41 08
Result:
07 01 00 4D 4E 41 53 55 48 44 39 38 33 2D 50 00 00 00 08
S U H D 9 8 3 - P
Reads the scaler and Ethernet firmware version.
Command (hex)
Description
Values
07 01 01 47 56 45 08
Reads the Scaler and Ethernet firmware version(6 Bytes).
—
Read the Scaler and Ethernet firmware version:
07 01 01 47 56 45 08
Result:
07 01 00 47 56 45 30 30 30 39 00 32 08
0 . 0 . 0 .9 - 0 2