Serial Command Reference
Mirage WQ-L User Manual
88
020-101372-01 Rev. 1 (04-2014)
Keypad IR Sensor Disable (KEN)
Local Setting (LOC)
KEN
CONTROL GROUP:
Preference
SUBCLASS:
Power Down
ACCESS LEVEL:
Operator
Description
Enable or disable the IR or wired keypad sensors. You cannot disable the keypad that is currently being used.
Subcode
FRNT
Description of Use
Set to 1 to enable the front IR keypad sensor, 0 to disable
.
WIRE
Set to 1 to enable the wired keypad jack, 0 to disable
.
Examples:
(KEN+FRNT 0) Disable front IR sensor.
(KEN+WIRE?) Get current wired jack enabled state.
LOC
CONTROL GROUP:
Preference
SUBCLASS:
Power Down
ACCESS LEVEL:
Advanced
Description
Set the localization options such as language and display options for temperature units.
Subcode
LANG
Description of Use
Set the system language:
0 - English 4 - Italian
1 - French 5 - Chinese
2 - German 6 - Japanese
3 - Spanish 7 - Korean
TEMP
Set the temperature units:
0 - Celsius
1 - Fahrenheit
Examples:
(LOC+LANG 1) Set language to French.
(LOC+LANG ?) Get language.
(LOC+TEMP 1) Set temperature to Fahrenheit.