P 3 5 G P S D u a l L e n s T u r r e t P r o j e c t o r
CHRISTIE INCORPORATED
P35GPS Projector
6-2
June, 1998
6 . 1 . 1 . P
R E L I M I N A R Y
P
R O C E D U R E S
on page 3-3 for a list of the tools, equipment, and materials required.
1.
Verify that LED is operational and lens is clean.
2.
Verify cell wiring for proper left/right wiring to cinema processor.
6 . 1 . 2 .
C
E L L
P
O S I T I O N I N G
: V
E R T I C A L
A
L I G N M E N T
1.
Loosen 3/32-inch Allen set screw on side of cell adjustment assembly (item 1 in
2.
Run Dolby Cat. 69 tone.
3.
Adjust vertical position of cell (item 2 in Figure 6-1) for maximum output level.
4.
Tighten set screw on side of cell adjustment assembly.
5.
Adjust cinema processor's pre-amplifier gains for left and right tone reference levels.
6 . 1 . 3 . H
O R I Z O N T A L
A
L I G N M E N T
1.
Loosen 3/32-inch Allen set screw on bottom of cell adjustment assembly (item 3 in
2.
Run Buzz Track film.
3.
Adjust lateral position of cell (item 4 in
) until there is no output at processor's
test points. If output is present on both left and right test points, increase focal distance
between lens and cell.
4.
Tighten set screw on bottom of cell adjustment assembly.
6 . 1 . 4 . F
O C U S A N D
A
Z I M U T H
1.
Loosen 3/32-inch Allen Azimuth set screw in hole on side of cell adjustment assembly
(item 6 in
2.
Turn cinema processor's pre-amplifier Hf
adjustments counterclockwise to minimum
settings.
3.
Run Dolby Cat. 69 Pink Noise film (not older than 1992).
4.
Adjust Focus (item 5 in
) and Azimuth (item 7 in
) for maximum
high frequency response and phase coherence.
5.
Carefully lock focus adjustment (5)
and azimuth set screw (6).
6.
Turn cinema processor's pre-amplifier Hf
adjustments clockwise until real-time analyzer
shows flat frequency response to 16 kHz.
7.
Verify that both channels have identical frequency response.