7. Remove the top portion of light engine cover.
Use caution when removing, the RTSM #3 temperature sensor is attached to the cover.
8. Place the cover on the card cage plate ensuring that nothing can get caught on the moving fan
blades and the RTSM#3 on the intake duct is away from the lamps.
Adjusting convergence
When adjusting convergence, never attempt to adjust the red DMD. Red is used as the reference color.
Green is adjusted first in relation to the red. Blue is adjusted second in relation to the green.
Note the following when adjusting convergence:
•
Boresight must be correct before adjusting convergence.
•
Do not adjust the plungers.
•
Convergence adjustment screws are sensitive. A small rotation can cause a large convergence
shift.
Warning! If not avoided, the following could result in death or serious injury.
•
UV EXPOSURE! Protective UV safety glasses with side shields and Christie approved protective
safety clothing must be worn when performing optical adjustments or servicing the product.
1. Power on the projector and wait 20 minutes for it to warm up.
2. To unlock the formatter, loosen the four lock-down screws.
Service setups
M Series Service Guide
21
020-100551-11 Rev. 1 (01-2019)
Copyright
©
2019 Christie Digital Systems USA, Inc. All rights reserved.