Damage to the projector.
Calibrate the lens motors when any of the following conditions are met:
•
After a lens change.
•
After the projector is moved and/or jostled.
•
After any manual adjustment is made to the zoom or focus.
To calibrate the lens:
1. Select MENU > Configuration > Lens Settings > Lens Calibration.
2. Select Enter.
Removing the projection lens
Use the correct method of removing the lens.
1. Remove and retain the two security screws (A), for installation, from the lens mount.
2. Rotate the lens clamp (B) counter-clockwise to the open position.
3. Slide the lens straight out of the projector.
If the lens does not slide out easily, reset the lens offset before removing the lens.
4. Attach the lens cap to avoid damage.
Installation and setup
Christie M RGB Series Installation and Setup Guide
28
020-103483-04 Rev. 1 (04-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.