3 Service Setups
This section describes special internal hardware and software adjustments and related details that may require
the attention of a qualified service technician, whether done periodically or after a specific module
replacement. The following table lists the most common alignment procedures required after a specific part is
replaced.
Table 3.1 Alignments/Procedures
Part Description
Required Alignments/Procedures
Ceramic Plate (on Douser blade)
• Adjust LampLOC
™
Cold Mirror
• Adjust LampLOC
™
• Recalibrate Measured Color Gamut Data (MCGD)
Douser Motor
• Adjust LampLOC
™
Fold Mirror
• Adjust Fold Mirror alignment
Illumination Optics System (IOS)
• Adjust Yellow Notch Filter
• Recalibrate color
• Define footlamberts
(optional)
Integrator Assembly
• Integrator alignment
• Fold Mirror alignment
Lamp
• Adjust LampLOC
™
Lamp Power Supply (LPS)
• Adjust LampLOC
™
Lens Mount Kit (Motorized or Non-
Motorized)
• Boresight adjustment
Light Engine
• Recalibrate color
• Define footlamberts
(optional)
Reflectors, 12" Glass
• Adjust LampLOC
™
UV Filter
• Adjust LampLOC
™
Vane Switch (Exhaust)
• Adjust LampLOC
™
Yellow Notch Filter
• Adjust YNF screw for accurate green coordinates
• Recalibrate color