Return the local time:
(TMD+TIME?)
Result:
(TMD+TIME! "12:18:49")
Adjust the SM clock by 120 seconds:
(TMD+TOFF 120)
UID–User ID
Allows users to log into the serial interface.
Parameters
•
Access level: None
•
Power level (minimum): Power Down
Commands
Command
Description
Values
UID?
Returns the current logged in user and their access level. (Read-
only)
The following are valid access permissions:
0 = None
10 = SNMP
20 = Operator
30 = Manager
40 = Installer
50 = Marriage
60 = Service
65 = ServicePlus
70 = Engineering
80 = Factory
—
UID <username>
<password>
Logs in with the username and password.
username = String
value
password = String
value
UID
Logs out the current user. This also happens when a new user logs
in.
—
C
™
serial commands
C Technical Reference–Serial Commands
29
020-103075-05 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Summary of Contents for CineLife+ 4 Series
Page 1: ...Technical Reference 020 103075 05 CineLife Serial Commands...