Command
Description
Values
KEN+WIRE?
Returns the current wired jack enabled
state. (Read-only)
—
KEN+WIRE <0 | 1>
Enables or disables the wired keypad sensor.
(Saved value)
0 = Disables the wired keypad jack
1 = Enables the wired keypad jack (Default)
Examples
Get the current wired jack enabled state:
(KEN+WIRE?)
Disable the front IR sensor:
(KEN+FRNT 0)
Disable the rear IR sensor:
(KEN+REAR 1)
LAS–Light & Output Settings
Configures the laser drive levels and uses the projector's LiteLOC
™
feature.
Commands
Command
Description
Values
LAS+BLUP <value>
Sets the drive level of the blue lasers. The
actual value sent to the laser rack is
reduced based on the Master Laser Power.
Expressed as percentage with one decimal
point.
0 to 1000, where 1000 = 100%
635 (Default)
LAS+CSRX?
Returns the color sensor X reading. (Read-
only)
Only applies to: Christie M RGB Series and
Griffyn Series
—
LAS+CSRY?
Returns the color sensor Y reading. (Read-
only)
Only applies to: Christie M RGB Series and
Griffyn Series
—
LAS+CSRZ?
Returns the color sensor Z reading. (Read-
only)
Only applies to: Christie M RGB Series and
Griffyn Series
—
LAS+EBLU <0 | 1>
Enables or disables the blue lasers.
0 = Disables the blue lasers
1 = Enables the blue lasers (Default)
LAS+EGRN <0 | 1>
Enables or disables the green lasers.
0 = Disables the green lasers
Serial API commands
Christie Technical Reference–Serial Commands
39
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.