EME–Enable Asynchronous Serial Messages
Enables or disables the asynchronous serial messages that the projector occasionally transmits.
Commands
Command
Description
Values
EME <0 | 1>
Enables or disables asynchronous serial
messages. (Saved value)
0 = Disables all asynchronous FYI/ERR
serial messages
1 = Enables asynchronous FYI/ERR serial
messages (Default)
Examples
Disable all asynchronous serial messages:
(EME 0)
Enable all asynchronous serial messages:
(EME 1)
ETP–Engine Test Pattern
Enables or disables the engine diagnostic test patterns.
Commands
Command
Description
Values
ETP <index>
Enables the engine diagnostic test
patterns, indicated by the <index>
parameter. This command is only
available if video electronics are on.
0 = Flat Black
1 = Green
2 = Red
3 = Blue
4 = White
5 = 8x8 Green Checker
6 = 8x8 Red Checker
7 = 8x8 Blue Checker
8 = 8x8 White Checker
9 = Convergence Border & Cross (Green)
10 = Convergence Border & Cross (Red)
11 = Convergence Border & Cross (Blue)
12 = Convergence Border & Cross (White)
13 = Convergence Border & Cross (Multi-color)
14 = Convergence Border & Square (Green)
15 = Convergence Border & Square (Red)
Serial API commands
Christie Technical Reference–Serial Commands
29
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.