Serial Command Reference
Matrix StIM™ WQ/SIM WQ User Manual
105
020-100883-01 Rev. 2 (06-2013)
Test Pattern Grey (ITG)
Internal Test Pattern (ITP)
ITG
CONTROL GROUP:
Unsaved
SUBCLASS:
Power Up
ACCESS LEVEL:
Operator
Description
Specify the grey level to use for the 'Grey' flat field internal test pattern. Range 0-1023. The level defaults to 512
on power up. This command is on available while the grey test pattern is being displayed.
Subcode
<No Subcode >
Description of Use
Example:
(ITG 512) Set test pattern grey to mid point.
ITP
CONTROL GROUP:
Unsaved
SUBCLASS:
Power Up
ACCESS LEVEL:
Operator
Description
Puts a test pattern on the screen or queries the test pattern currently displayed. Select which test pattern to
display from the list:
0 = Off
1 = Grid
2 = Grey Scale 16
3 = White
4 = Flat Grey
5 = Black
6 = Checker
7 = 13 Point
8 = Color Bars
12 = Edge Blend
14 = Boresight
Subcode
<No Subcode >
Description of Use
Enable, disable or change standard test patterns.
Example:
(ITP 0) Disable test patterns - revert to previous Input signal.
(ITP 1) Set test pattern to the grid pattern.