background image

Replacing the Boxer

lens circuit boards

The lens circuit board projector (LCBP) must be connected to lens circuit board lens (LCBL) for the

lens zoom motor to work.
To ensure a proper connection between the LCBP and LCBL for lens zoom functionality, Christie has
released a new service kit to replace worn or damaged parts.

Affected products

The following products are affected.

Boxer 4K models

Boxer 2K models

Boxer 30

Mirage 304K

Required components

The following components are required to complete the upgrade.

Boxer lens repair kit LCBL and LCBP P/N: 003-006191-01

Tools required for installation

Make sure the following tools are available during the installation:

Long and stubby neck magnetic-tip ball drivers—2.5 mm, 3 mm, and 5 mm provided in
projector toolbox

Needle nose wire cutter

2.5 mm hex driver

3 mm hex driver

 

Replacing the Boxer LCBP and LCBL Instruction Sheet

1

020-102501-01 Rev. 1 (11-2016)

Copyright 

©

 2016 Christie Digital Systems USA Inc. All rights reserved.

Summary of Contents for 003-006191-01

Page 1: ...dels Boxer 2K models Boxer 30 Mirage 304K Required components The following components are required to complete the upgrade Boxer lens repair kit LCBL and LCBP P N 003 006191 01 Tools required for installation Make sure the following tools are available during the installation Long and stubby neck magnetic tip ball drivers 2 5 mm 3 mm and 5 mm provided in projector toolbox Needle nose wire cutter ...

Page 2: ...amage SHOCK HAZARD All harnessing must be properly routed and secured as originally installed especially in high voltage areas Turning the projector off When powering off in preparation for inspection or maintenance always disconnect from AC 1 To turn the lamps off press and hold the Power button until you hear a beep When powering off the projector allow the projector to complete its cool down cy...

Page 3: ...he physical contact control between the lens and the projector for operation of the zoom motor on the lens Estimated replacement time 1 5 minutes 1 If installed remove the lens 2 Remove the two screws securing the lens mount board 3 Disconnect the J2 harness 4 Pull out the board 5 Replace the board 6 To re install follow these steps in reverse order Replacing the lens connector board lens The lens...

Page 4: ...e products is available at North and South America 1 800 221 8025 or Support Americas christiedigital com Europe Middle East and Africa 44 0 1189 778111 or Support EMEA christiedigital com Asia Pacific 65 6877 8737 or Support APAC christiedigital com Replacing the Boxer lens circuit boards Replacing the Boxer LCBP and LCBL Instruction Sheet 4 020 102501 01 Rev 1 11 2016 Copyright 2016 Christie Dig...