background image

Operation 

Connection 

The MU-series keyboards can be used directly with a PC or Mac computer to provide MIDI control in a software sound module or 
multi-track recording package. For this application, the USB socket on the rear panel should be connected to a spare USB port 
on the computer (a USB lead is supplied for this) 

– this will transfer MIDI to the computer and provide power to the MU-series 

keyboard. The MIDI OUT can also control external devices in this setup. 
 
The MU-series keyboards can also control MIDI devices when not connected via a computer, by connecting the MIDI OUT to the 
MIDI input of the controlled device and powering the MU-series keyboard via an optional 9Vdc power adapter. 
 

Assignable Controllers 

 
Press the EDIT button and the EDIT LED will be light to indicate that the note keys are in EDIT mode. 
Press the ASSIGN key to enter controller assign mode, the LED display will show CHO, prompting the user to 

“choose” the 

controller that needs to be assigned.  
Operate the required controller to select it (e.g. to assign SLIDER, move the Slider to select it) 
The LED display will show the MIDI controller number of the selected controller 
Input the desired assignable parameter value with number keys (0-9), and press ENTER to confirm  
(e.g. if Slider is selected, input 

“1”, ”4”, ”7” and the Slider will be set to MIDI control 147 - Master Volume). 

Assignable controller reference: Appendix 1- Assignable controller List 
Assignable controller parameters reference: Appendix 2 - Assignable Controller Parameter List. 
 

Pedal Resistance Curve (MU49, MU61) 

The response curve of the pedal interface can be tailored to match control pedals with different specifications and electrical 
resistance values. This can be adjusted by trial and error, testing the response of the pedal for various values. Alternatively, it 
can be calculated as follows… 

To calculate the resistance curve value for Pedal A (PA CURVE) or Pedal B (PB CURVE) 
  

Curve = (128 x Pedal resistance value) / (10K + Pedal resistance value). 

 
For example, if the pedal resistance value is 10K, the value of PA Curve or PB Curve is

… 

 

128 x10K / (10K + 10K) = 64.

 

 

For the pedal

’s electrical resistance value, please refer to the technical specifications provided by pedal manufacturer. The initial 

value of resistance curve is 64, adaptable to most control pedals in the market.  
When using a switching type pedal, the recommended resistance curve value is also 64.  
When DATA +/- is assigned as PA CURVE or PB CURVE, the DATA +/- buttons can be used to adjust resistance curve values. 

Press both DATA + and - simultaneously 

to set the resistance curve value to initial 64.  

When the dials (R1-R4 or R5-R8) are assigned as PA CURVE or PB CURVE, they can be used to adjust pedal resistance value.  
Press EDIT button to enter keyboard multi-function mode, press PA CURVE or PB CURVE multi-functional keys to enter pedal 
resistance curve adjustment mode, input the pedal resistance value with numeric pad, then press ENTER to confirm.

 

 

TEMPO (MU49, MU61) 

Press the EDIT button and the EDIT LED will be light to indicate that the note keys are in EDIT mode. 
Press the TEMPO key to enter tempo adjustment mode, then input the tempo value with number keys. Press the ENTER key to 
confirm.  
When DATA +/- is assigned as TEMPO, it can be used to adjust MIDI tempo.  
Press both DATA + and - simultaneously to set the tempo to the initial value = 100 
Likewise, the dials (R1-R4 or R5-R8) can be assigned to adjust TEMPO 

PROGRAM 
 

Press the EDIT button and the EDIT LED will be light to indicate that the note keys are in EDIT mode. 
Press the PROGRAM key to enter program select mode, then enter the number with the number keys.  
Press the ENTER key to confirm.  
When DATA +/- is assigned as PROGRAM, DATA +/- can be used to adjust the program (or voice). Press both DATA + and - 
simultaneously to set the program to the initial value = 0 
Likewise, the dials (R1-R4 or R5-R8) can be assigned to adjust the PROGRAM number 
 

MIDI Channel 
 

Press the EDIT button and the EDIT LED will be light to indicate that the note keys are in EDIT mode. 
Press the CHANNEL key to enter MIDI channel select mode, then set the channel with the number keys.  
Press the ENTER key to confirm.  
When DATA +/- is assigned as CHANNEL, DATA +/- can be used to adjust the MIDI channel  
Press both DATA + and - simultaneously to set the program to the initial value = 0 
Likewise, the dials (R1-R4 or R5-R8) can be assigned to set the MIDI channel 

 

Summary of Contents for MU25

Page 1: ...y 5 x velocity curves and selectable keyboard split Assignable control pedal switch or continuous inputs 1 for MU25 2 for MU49 MU61 Assignable slider control Pitch Bend Wheel and Modulation Wheel assi...

Page 2: ...not allow any foreign particles to enter the keyboard through connectors or control apertures Placement Position the keyboard on a solid flat surface or strong stable keyboard stand with adequate grip...

Page 3: ...LED Display Shows program parameter values for MIDI and EDIT functions 9 SWITCH Button Toggles the rotary dials between 2 groups of control settings R1 R4 R5 R8 10 Dial Function Group LEDs Indicate w...

Page 4: ...x10K 10K 10K 64 For the pedal s electrical resistance value please refer to the technical specifications provided by pedal manufacturer The initial value of resistance curve is 64 adaptable to most c...

Page 5: ...and MTC again switches this function off again Active Sensing MU49 MU61 Pressing the EDIT button followed by the ACT key sets Active Sensing FE to be transmitted from the keyboard to the device it is...

Page 6: ...le equipment controlled by the keyboard message F0 7E 7F 09 01 F7 GM2 ON MU49 MU61 Pressing the EDIT button then the GM2 ON key transmits the GM2 initialisation message This switches on the General MI...

Page 7: ...nto Control 0 0 127 85 90 Controller 0 0 127 91 Reverb 40 0 127 92 Effects 0 0 127 93 Chorus 0 0 127 94 Effects 0 0 127 95 Effects 0 0 127 96 RPN Increment 0 0 127 97 RPN Decrement 0 0 127 98 NRPN LSB...

Page 8: ...FICATIONS 1 Keyboard MU25 25 Keys C2 C4 Initial Touch MU49 49 Keys C1 C5 Initial Touch MU61 61 Keys C1 C6 Initial Touch 2 Function MIDI Data Program Select Bank Select Sequencer Control MTC Controller...