background image

Air Curling 

332-C1904

� CEJ CTJ 

CD 

li 

0000 mllllm 

�E)E)E) 

Read this manual carefully before use and save it for later use. 

This device is NOT FOR MEDICAL USE. 

Summary of Contents for 332-C1904

Page 1: ...Air Curling 332 C1904 CEJ CTJ CD li 0000 mllllm E E E Read this manual carefully before use and save it for later use This device is NOT FOR MEDICAL USE ...

Page 2: ...ories 07 Component Names 08 Display Window 09 Function buttons l0Nll How to use this produet 12N14 Maintenance 15 Specifications Warranty ard 16 Troubleshootings 17 MEMO 18N19 a a DD s l ooo oot Air compressed cuff LED Vartous massage 111 lmin 4 Levels of pressure Wireless with four chambers Display programs Air pump adjustment Control 02 ...

Page 3: ...any injuries or damages and operate it properly using this produet Please read thoroughly and keep it in a near place to read it next time O WARNINGS 8 _l_ 8 S PROHIBITIONS oo OBSERVANCE USE PURPOSE It relaxes your legs arms and waist by inflating and deflating the air cuffs 03 ...

Page 4: ... reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 08 lf the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qu...

Page 5: ...t your local distributor 06 Be careful that water or dirty materials do not go into the cuffs 07 After use The air in the air boots goes out fully and then keep it in a proper place 08 Do not put other things on this produet 09 Plug it off in case of not using for a long time 10 Be careful that the air hoses are not twisted or pressed during use or keeping 11 Keep this produet in a proper place 12...

Page 6: ...eart disease 8 Allergy Other prohibited things 1 Take things out from your clothes befare use 9 Cerebral hemorrhage 10 Tuberculosis 11 Drinking alcohol or taking a medicine 12 The pregnant 13 Malignant tumor 14 Under bad health condition 15 Heavy fatigue 16 People who have been diagnosed by doctors as inappropriate to use this machine 2 Consult with a doctor if you feel something wrong with your b...

Page 7: ...roduet Accessories Device Accessories Device 1 pair of leg cuff Remote controller Foot plate Foot plate Device 1 pair af leg cuff Remote centroller Option Arm Cuff Wasit cuff Half Pants cuff Extender 07 ...

Page 8: ...Component Names 08 0 Portable grip f Operation display window E Operation buttons 0 Air socket Ø Silicone hose Ø T connector 0 Hose plug Q Legcuff Ø Velcro wrap ...

Page 9: ...LED light ON Inflation or Keeping the inflation ø MODE Button OFF Inflation or Deflation 4 Modes can be chosen e Display of MODE A B C D ø SELECT Button MODE A is selected when you turn it on and It can select desired chamber you want you can choose another mode Ø Pressure level Display f Pressure Adjustment Button It can adjust pressure by 4 steps It displays the status of pressure level 09 ...

Page 10: ...er 20 minutes 8 MODE 1111 I EtIJ Etil ttiJ 0 8 0 0 Press the MODE button if you want to change it to B C and D Refer to the program below lf you press the SELECT button during use The MODE lamp gets off and the lamp on the chambers gets on D MODE It repeats the modes ofA Band C in arder Arm Cuff Optional Waist Cuff Optional Optional ruffs also have 4 chambers as the same as the legcuff ...

Page 11: ...hanged whenever the SELECT button is pressed Once Twice Three Four times times 1 I il 1 Five Six Seven Eight times times times times l aa 1 a 1 a Nine Ten times 1 times 1 0 PRESSURE It consists of 4 pressure levels and you can select it as you press the button Deflating function is working temporarily in case the PRESSURE button is pressed 11 ...

Page 12: ...trol unit making sure the arrow sign is facing up 3 The hose plug should be connected fully to prevent air from leaking out 8 Wearacuff 1 Wear a light clothes to use this produet 2 Check left and Right cuff for leg cuff Protecting cover Cover the protecting coverto protect your skin 3 Pull the zipper up to the end and be careful that your clothes stocking and others are not caught in zipper ...

Page 13: ...rol v ro Attach the velcro to prevent any harms on cuffs and your body 1 Read Page 9 to page 11 in detail to know about the operation and function buttons 2 Place the produet in a flat area 3 The changed operation starts after deflating the air in the air cuffs for 3 second in case other function buttons are pressed during use 13 ...

Page 14: ... velcro firmly 8 Wearing a waist cuff optional an arm cuff optional Half Pants Cuff Optional WARNINGS Wearing an arm cuff Wearing a waist cuff 1 Select the compression strength from low level to high level 2 Do not move around wearing a cuff Extender It is recommended for a big person Wearing a Half Pants Cuff ...

Page 15: ...nger of drop or shock Do not clean it with flammable chemicals Just clean a produet body with a soft cloth Keep it dry after cleaning It should be stored out of children s touch Disconnect the power cord if you don t use it for a long time The Maintenance ofa cuff Ø Clean sweat or water in a cuffwith a dry cloth and dry it fully Clean it with a soft cloth and do not clean with flammable chemicals ...

Page 16: ...on Weight Packing Produet body size Origin WARRANTY CARD Produet Name Model Name Date of Purehase Warranty CUSTOMER 16 Name Tel Dealer AIR LEG MASSAGER 332 C1904 AC 100 240 V 50 60Hz 30W 2 3 kg lset 230 W x 230 0 x lS0 H mm MADE IN KOREA AIR LEG MASSAGER 332 C1904 1 year from date of purehase ...

Page 17: ...r checking the below points Is it power failure Is a power cord not connected Is the connection to an electric outlet ok Is it lighting on the LCD display The floor is flat Is it broken Are air hoses folded Are the air boots torn Do the correct measures after checking the below points Wait until the power is on Plug in a power cord Use another electric outlet Press the ON OFF button again Move it ...

Page 18: ...MEMO 18 ...

Page 19: ...MEMO 19 ...

Page 20: ...l REV 20 10 16 CE Chiroform A S Mariendalsvej 22 8800 Viborg Denmark Tel 45 8661 3611 chiroform chiroform dk www chiroform dk Air Curling 332 C1904 ...

Reviews: