正常に作動しない場合の対策

Countermeasures against Abnormal 

Operation 

 
 

故障現象

 

Failure phenomenon

 

原因

 

Cause

 

対策・方法

 

Countermeasures

 

①モ-タが起動しない。

 

運転中に突然停止した。

 

The motor is not started. 
The motor stops suddenly 
during operation.

 

電源が入っていない

 

The power is not turned ON.

 

電源を入れる

 

Turn ON the power. 

モータ焼け

 

Motor seizing 

モータ交換(修理依頼願います)

 

Replace the motor.    (Ask for repair.) 

過負荷・異常温度

 

により、停止した。

 

The motor stops due to 
overload or abnormal 
temperature. 
 

[1] 

排気口

/

吸引口が塞がれていないか確認

 

(完全にふさがれると過負荷ランプが点灯します)

 

Check whether the exhaust port and suction port 
are not clogged. 
  (When  they  are  fully  clogged,  the  overload 
lamp is turned on.) 

[2] 

定格電圧の確認。

 

(タコ足配線になっていないか)

 

Confirm the rated voltage.     
(Confirm  that  a  star-burst  connection  of  several 
plugs in one outlet is not adopted.) 

[3] 

フィルタの目詰まりによりモータが過熱していないか
確認。

 

Confirm  that  the  motor  is  not  overheated  by 
clogged filters. 

(1)~(

3

)の確認後、原因を取り除き、リセットスイッチを

押す。(リセットは、主電源スイッチの入切でもできます)

 

リセットしても、運転が再開できない場合は、モータの温度
サーマルが働いている可能性がありますので、主電源を
切り、

30

分経過してから、運転を開始してください。

 

After checking (1) to (3) above, remove the cause of 
error, and press the RESET switch.    (Or turn OFF 
and ON the MAIN POWER switch to reset the error 
status. Start the operation 30 minutes later.) 

ヒューズが切れた

 

Fuses are blown out 

ヒューズを交換する(ヒューズについて参照)

 

Replace fuses. (Refer to 

“Fuse”) 

②吸引力低下

 

The suction force is 
deteriorated. 

フィルタの目詰まり

 

Filters are clogged. 

フィルタ交換

 

(目詰まりを放置すると③④の故障となります)

 

Replace filters. 
(Clogged filters lead to the failures [3] and [4] below.) 

③粒子吹きもれ

 

Particles are not blown 
completely. 
 

フィルタ取り付け不良

 

Filters are not installed 
correctly. 

フィルタの取付け

 

Install filters correctly 

フィルタの破損、寿命

 

Filters are damaged, or 
their life is expired. 

フィルタ交換

 

Replace filters 

フィルタの目詰まり

 

Filters are clogged. 

フィルタ交換

 

Replace filters. 

④送風機異常音、

 

異常振動

 

  The blower is generating 
abnormal sounds or 
abnormal vibrations 

ブロア内への異物混入

 

Foreign substances have 
entered the blower. 

修理依頼願います

 

Ask for repair. 

電動機軸受けの破損

 

The motor bearing is 
damaged. 

電動機交換(修理依頼願います)

 

Replace the motor.    (Ask for repair.) 

⑤「

E.EE

」が表示した場合

 

 

配管の圧力損失が高いた
め、風量低下している

 

 

[1] 

配管を最短距離にする

 

[2] 

配管径を大きくする

 

 

⑥異常ランプが点灯した

 

場合

 

異常温度又は、インバーター
に(過負荷など)異常が発生
した。

 

電源を再投入してください。復帰しない場合は、メーカに
お問い合わせください。

 

Summary of Contents for CKU-080AT2-HC-CE

Page 1: ...that you can use it safely for a long time and enjoy its full performance Symbols used in this manual WARNING This symbol indicates actions that should not be performed in any case or actions that may...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...irmation before operation 10 4 5 Operation procedure 11 4 6 C CC 11 4 7 E EE 12 4 8 12 5 Remote Cable Sold Separately 13 5 1 Electrical circuit diagram 13 5 2 Color and signal of each wire 14 6 Mainte...

Page 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Page 5: ...of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately if parts are damaged during...

Page 6: ...e of main body AT AT Panel operation panel Suction port Desorption type MAIN POWER switch BOX Fuse Box Remote connector CKU 450AT2 HC CE V1 MAIN POWER switch Differential pressure sensing gauge Consol...

Page 7: ...ine dust and fumes Secondary filter Protecting the circuit and the electrical parts Exhaust filter Exhaust treatment 3 3 Desorption flange CKU 080AT2 CKU 240AT2 CKU 080AT2 HC 50 38 CKU 240AT2 HC 65 50...

Page 8: ...anel Operating the product with a different power supply may cause a failure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is required for startup ON...

Page 9: ...7 3 3 0 9 99KPa E EE 1 7 0 2 Pa 0 2 Pa The pressure representation when operation stops changes within the range from 0 2 to 0 2 Because there is a change in the atmospheric pressure and the temperat...

Page 10: ...mp of AT panel lights AT ON Press the ON switch AT Panel to start operation The operation indicator lamp lights Confirm that abnormal sounds such as metallic sounds are not generated Confirm that the...

Page 11: ...ator lamp lights Starts the dust collector AT ON Press the ON switch to start the operation Confirm again that abnormal sounds are not generated and confirm that the suction hose offers proper suction...

Page 12: ...Copyright CHIKO AIRTEC CO LTD 2009 12 4 7 E EE E EE 19 7 11 4 5 E EE 4 8 2 050 30 70 50 40 30 70 60 30 2 2 2 1 30...

Page 13: ...ND 7 GND Ability level change input signal 5 Remote Cable Sold Separately 5 1 Electrical circuit diagram Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the...

Page 14: ...ion switching signal Short circuits the wires 4 and 8 to start remote operation The AT panel is disabled while the wires 4 and 8 are short circuited Yellow 0 5 Yellow white Black White Operation press...

Page 15: ...signal of each wire ON OFF 5 3 Do not short circuit the wires 4 and 8 each other when transferring signals by turning ON and OFF the dust collector from the main body Transfer required output signals...

Page 16: ...ake sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspection Using a worn or damaged filter will release sucked du...

Page 17: ...ary filter from the filter case The paper packing of the primary filter is inserted into the cylindrical pipe of the filter case Pull the paper packing toward you to remove the primary filter 2 Open t...

Page 18: ...ody Once day Are no abnormal vibrations or sounds generated Is the installation level correct Filter installation status Once month Are the filters installed securely Filter clogged status Suction for...

Page 19: ...he motor is not overheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status S...

Page 20: ...Copyright CHIKO AIRTEC CO LTD 2009 20 8 Indication of DANGER Labels Electrical Circuit Diagram 8 1 CKU 080AT2 HC T CE MODEL...

Page 21: ...Copyright CHIKO AIRTEC CO LTD 2009 21 8 2 CKU 240AT2 HC T CE MODEL...

Page 22: ...Copyright CHIKO AIRTEC CO LTD 2009 22 8 3 CKU 450AT2 HC T CE MODEL...

Page 23: ...2 50 60 7 0 2 9 58 73 30 5 CKU 450AT2 HC T 450 200V Single phase 4 2 50 60 7 0 2 9 58 73 30 5 CKU 450AT2 HC CE 450 220 240V Single phase 4 2 50 60 7 0 2 9 58 73 30 5 1 dB Note The Noise column indica...

Page 24: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: