Chapter 7 Appendix
58
Chapter 7
Appendix
7.1
Specifications
Model
Motor rated
output
Voltage
Current
value
Frequenc
y
Max. suction
volume
Max. suction
static pressure
Noise
value*
1
Mass
CKU-060AT3-ACC
50W
100 V*
2
single phase
2.3 A
50/60Hz 2.8m
3
/min
2.5kPa
53 to 61 dB 15.8kg
CKU-060AT3-ACC-T
200 V
single phase
1.5 A
CKU-060AT3-ACC-CE
220 to 230 V
single phase
1.4 A
*1: Noise value is measured with a hose connected to the suction port, at a distance of 1 m from the
device, on the A scale dB.
*
2 Can be used in the area of 100-115V.
7.2
Consumables List
Part name
Replacement intervals
*1
CKU-060AT3-ACC (-T,-CE)
Primary filter
1 to 3 months
CHF-2222-40
Secondary filter
3 to 6 months
ACC-2525-75ST
Tertiary filter
6 to 12 months
CHF-2525-50
*1: The replacement intervals vary with the use frequency, environment, and suction concentration
(substance and composition) at the customer’s site.