background image

I N S T A L L A T I O N   I N S T R U C T I O N S

Fixed Wall Racks

Spanish Product Description
German Product Description

 Portuguese Product Description

 Italian Product Description

Dutch Product Description

French Product Description

NW2F8-12

Summary of Contents for NW2F8-12

Page 1: ... O N I N S T R U C T I O N S Fixed Wall Racks Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description NW2F8 12 ...

Page 2: ...es the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located w...

Page 3: ...Installation Instructions NW2F8 12 3 DIMENSIONS NW2F818 NW2F1218 DIMENSIONS INCHES MILLIMETERS ...

Page 4: ...security included wood stud 7 32 concrete 5 16 steel stud 1 2 A 1 Wall rack B 1 Door C 1 Mounting plate D 4 5 16 E 4 Anchor F 4 5 16 x 2 1 2 G 4 1 4 20 x 1 3 4 H 4 1 4 J 4 1 4 20 snap toggle K 2 10 32 x 1 2 L 2 1 4 20 M 1 5 32 security N 1 Rack wire Model NW2F1218 shown for Parts A B C ...

Page 5: ...no other equipment should be mounted to the same stud See Figure 1 Figure 1 Must be centered on stud Drywall 1 2 minimum Drywall Thickness Display Mount Installation Location FRONT Both Sides of Stud There must be a minimum of 1 7 8 48mm clearance inside wall 16 or 24 on center Studs If back side of wall is unfinished drywall must be installed to a minimum of one stud left and right of the stud s ...

Page 6: ... of gas water waste or any other plumbing before cutting drilling or installing fasteners 1 Using the mounting plate C as a template mark the wall on each stud at the top mounting slots See Figure 2 2 Drill one 7 32 5 5mm pilot hole at both marks made in Step 1 See Figure 1 3 Use two 5 16 x 2 1 2 lag bolts F and two 5 16 flat washers D to attach top of mounting plate C to wall See Figure 2 4 Mark ...

Page 7: ...nstalling to a Steel Stud Wall IMPORTANT See Site Requirements section before proceeding with Steel Studs installation to ensure installation site meets requirements The drywall must have a minimum thickness of 1 2 Determine location of NW2 wall rack Use stud finder to locate steel studs WARNING ELECTRICAL SHOCK HAZARD CUTTING OR DRILLING INTO ELECTRICAL CORDS OR CABLES CAN CAUSE DEATH OR SERIOUS ...

Page 8: ...nchors and align top mounting holes in mounting plate with holes in anchors 9 Insert 1 4 20 x 1 3 4 Phillips pan head screws G through 1 4 washer H corresponding mounting hole on mounting plate and into anchor J and tighten until flush against mounting plate DO NOT overtighten See Figure 8 WARNING IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUI...

Page 9: ...9 3 Insert door into rack aligning the spring handle ends with the holes in the top and bottom of rack See Figure 10 Figure 10 4 Add one end of rack wire N to grounding stud at bottom of door See Figure 5 Tighten 1 4 20 nut L onto grounding stud See Figure 6 Place opposite end of rack wire to grounding stud on floor of rack See Figure 7 Tighten 1 4 20 nut L over rack wire and onto grounding stud S...

Page 10: ...g on rack LOADING THE RACK NOTE The alignment panels shipped with the racks are optional They may be removed to facilitate loading of the racks Load Distribution CAUTION BEGIN PLACEMENT OF LOAD AT BOTTOM OF RACK Load rack moving from bottom toward top of rack Loading rack incorrectly may result in instability causing possibly injury and or damage to components 1 Begin placement of components into ...

Page 11: ...from the bottom upward CAUTION The top of the unit should not be used as a shelf CAUTION DISTRIBUTE LOAD CORRECTLY Load rack with 2 3 total weight of components in the lower half of rack Loading rack incorrectly may result in instability causing possible injury and or damage to components ...

Page 12: ...d 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief Manufacturing a products division of Milestone AV Technologies 8821 002035 Rev00 2011 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 05 11 ...

Reviews: