background image

I N S T A L L A T I O N   I N S T R U C T I O N S

Instrucciones de instalación

Installationsanleitung

Instruções de Instalação

Istruzioni di installazione

Installatie-instructies

Instructions d´installation

LBM2X2U

LBM3X2U

LBM3X3U

LBM3X1UP

LBM2X2UP

LBM3X2UP

Bolt Down Video Wall

Spanish Product Description
German Product Description

 Portuguese Product Description

 Italian Product Description

Dutch Product Description

French Product Description

LBM Series

Summary of Contents for LBM Series

Page 1: ...struzioni di installazione Installatie instructies Instructions d installation LBM2X2U LBM3X2U LBM3X3U LBM3X1UP LBM2X2UP LBM3X2UP Bolt Down Video Wall Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description LBM Series ...

Page 2: ...ponsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Do NOT stack multiple accessories on the same display wall Do NOT connect accessories to walls that are already three display high Display walls may NOT be stacked higher than three display...

Page 3: ... UL listed FCA3X1U and LBM2X2U may be used with UL listed FCA2X1U LBM3X1UP may be used with UL listed FCA3X1UP NOTE The LBM Series carts have no user serviceable parts SAVE THESE INSTRUCTIONS DIMENSIONS LBM2X2U MAX WEIGHT 125 LBS PER DISPLAY 500 LBS TOTAL CAPACITY 1 43 36 2 441 3 17 38 1673 2 65 88 1692 0 66 62 203 2 8 00 3 73 94 7 72 87 1851 0 64 38 MIN HEIGHT SCREEN CENTER 416 1 16 38 MAX HEIGHT...

Page 4: ...N CENTER 416 1 16 38 MAX HEIGHT SCREEN CENTER 2349 5 92 50 64 38 8 00 203 2 MAX WEIGHT 125 LBS PER DISPLAY 750 LBS TOTAL LBM3X3U 1 43 36 2 94 7 3 73 441 3 17 38 2130 4 83 88 2149 2 84 62 8 00 203 2 34 25 870 0 MAX HEIGHT SCREEN CENTER MIN HEIGHT SCREEN CENTER 2092 3 416 1 16 38 977 4 38 48 95 8 3 77 5 38 136 5 PATTERN HEIGHT MAX MOUNTING 400 0 2242 1 15 75 88 27 2 53 64 1 38 1 1 50 2765 4 108 87 2...

Page 5: ...Installation Instructions LBM Series 5 64 38 1635 1 SCREEN CENTER MAX HEIGHT 17 38 MAX WEIGHT 125 LBS PER DISPLAY LBM3X1UP 82 38 SCREEN CENTER MAX HEIGHT 17 38 MAX WEIGHT 100 LBS PER DISPLAY LBM2X2UP ...

Page 6: ...LBM Series Installation Instructions 6 82 38 2092 3 SCREEN CENTER MAX HEIGHT 17 38 MAX WEIGHT 100 LBS PER DISPLAY LBM3X2UP ...

Page 7: ... 4 42 00 1066 8 1 00 25 4 6 00 152 4 1 00 25 4 0 500 12 7 8 00 203 2 8 00 203 2 28 00 711 2 44 00 1117 6 LARGER RADIUS FACES FRONT TO ATTACH TO COLUMN COLUMN BOLT PATTERN NOT SQUARE 6 00 152 4 6 00 152 4 42 25 1073 2 48 25 1225 6 84 50 2146 3 90 50 2298 7 1 00 25 4 1 00 25 4 8 00 203 2 8 00 203 2 0 500 12 7 BOTTOM VIEW FOR BOLT DOWN INSTALLATION LBM2X2U LBM3X1UP LBM3X2U LBM3X3U LBM2X2UP LBM3X2UP ...

Page 8: ... Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perfora...

Page 9: ...4 36 750x 344x 5 F 16 24 36 M8x12mm G 16 24 36 M8x16mm H 16 24 36 M8x25mm I 8 12 18 1 4 20 x 1 1 4 J 2 3 3 bolt down plate K 2 0 0 dual display rail L 0 2 3 triple display rail M 2 3 3 cart array column N 2 3 3 column cap P 4 6 9 clamp bracket Q 4 6 9 quick connect base R 8 12 12 5 16 18 x 1 1 2 T 1 1 1 3 16 hex bit U 8 12 12 3 8 x 3 anchor V 0 0 3 column add on W 0 0 18 1 4 20 x 1 2 X 0 6 9 10 24...

Page 10: ... 20 x 1 1 4 J 2 2 2 bolt down plate K 1 2 2 portrait display rail L 0 0 0 triple display rail M 2 2 2 cart array column N 2 2 2 column cap P 2 4 4 clamp bracket Q 2 4 4 quick connect base R 8 8 8 5 16 18 x 1 1 2 T 1 1 1 3 16 hex bit U 8 8 8 3 8 x 3 anchor V 0 2 2 column add on W 0 12 12 1 4 20 x 1 2 X 0 0 0 10 24 x 1 1 2 Y 3 4 6 left interface Z 3 4 6 right interface AA 2 4 4 5 16 18 x 4 1 2 BB 16...

Page 11: ...ORTANT See Bolt Down Dimensions on page 6 to measure distances between each bolt down plate IMPORTANT Make sure columns will be installed far enough away from any walls so that displays may be installed 4 Using a 3 8 drill bit drill a hole 3 3 8 in depth at each marked location See Figure 2 and See Figure 3 5 Blow each hole clean of any concrete debris with a large air hose or compressed air in a ...

Page 12: ...e 5 Figure 5 3 Use 5 16 18 x 4 1 2 button head cap screw AA two 5 16 washers CC and 5 16 18 lock nut FF to secure each clamp bracket P to column See Figure 5 NOTE Clamp brackets P may be flipped in order to use long slots for installation if necessary See Figure 6 Figure 6 NOTE If installing LBM3X1UP proceed ahead to Step 6 4 Measure one screen height down from center point on installed clamp brac...

Page 13: ...oles on each quick connect base Q See Figure 9 Figure 9 8 Hang rails K or L into screws installed in previous step to quick connect bases Q See Figure 9 IMPORTANT If installing the triple display rail L install rail to left and center columns so that add on rail can be installed to right column See Add On Rail Installation section for details 9 Install two 5 16 18 x 3 4 button head flange screws B...

Page 14: ...s are required If mounting holes are recessed or if protrusions prevent brackets Y and Z from laying flat then spacers E must be used CAUTION Using screws of improper length may damage your display Proper screws will have adequate thread engagement without contacting bottom of display mounting holes 4 Select screw length See Figure 12 and See Figure 13 Using your hand insert SHORTEST length screw ...

Page 15: ...to either the LBM2X2U the LBM3X2U or the LBM3X1UP the weight limit for each display becomes 100 lbs 45 4 kg rather than 125 lbs 56 7 kg MODEL Max Weight Allowed for EACH Display Max Weight Capacity of Mounting System LBM2X2U 125 lbs 56 7 kg 500 lbs 226 8 kg LBM3X2U 125 lbs 56 7 kg 750 lbs 340 2 kg LBM3X3U 100 lbs 45 4 kg 900 lbs 408 2 kg LBM3X1UP 125 lbs 56 7 kg 375 lbs 170 1 kg LBM2X2UP 100 lbs 4...

Page 16: ...1 Use four 5 16 18 x 1 2 button head cap screws EE to install each column cap N to each column See Figure 15 Figure 15 Adjustments Height Adjustment 1 Use upper knob on back of interface brackets Y and Z to adjust the height of each display See Figure 16 NOTE Adjust both brackets in order to maintain a level mount Plumb Adjustment 2 Use middle and lower knobs on back of interface brackets Y and Z ...

Page 17: ...e management holes cables may be routed through quick connect bases Q prior to the rails being installed See Figure 19 4 Install rails according to Rails Installation section making sure cable is routed through cable opening on quick connect base Q See Figure 19 Figure 19 5 For any cable management holes that are not used snap covers KK may be used to cover holes as desired See Figure 20 Figure 20...

Page 18: ...LBM Series Installation Instructions 18 Figure 21 FRONT ...

Page 19: ...Installation Instructions LBM Series 19 ...

Page 20: ...klinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief Manufacturing a products division of Milestone AV Technologies 8800 002313 Rev02 2013 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 02 13 ...