background image

I N S T A L L A T I O N       I N S T R U C T I O N S

CHIEF MANUFACTURING INC.

8803-000031RevG

1-800-582-6480

  952-894-6280 FAX 952-894-6918

2003 Chief Manufacturing

12800 HIGHWAY 13 SOUTH, SUITE 500

www.chiefmfg.com

SAVAGE, MINNESOTA 55378  USA

08/06

100 DEGREE ANGLED CEILING PLATE WITH THREADED

COUPLER

CMA-395

The 100° Angled Ceiling Plate is designed for ease of installation with any height of ceiling.  By using any
length of standard NPT 1½” pipe threaded both ends, you can extend the height capabilities to meet your
needs.

WARNING:  IMPROPER INSTALLATION MAY RESULT IN SERIOUS PERSONAL INJURY!

When mounting Chief Manufacturing accessories, the structural system and mounting method

MUST

 be capable of supporting 5 times the combined weight of the total installation.

The maximum weight to be installed on the ceiling plate is 500 pounds (226.8 Kg).

Unpack and check contents:
  (1)  Cathedral Ceiling Plate CMA-395

(1)  Coupler Assembly

  (1)  5/16”-18 X 3/8” Set Screw

(1)  ½”-13 X 4” Hex Head Bolt

  (1)  ½”-13 

Nylock 

Nut

(2)  3/8”-16 X 5/8” Hex Machine Screw

  (2)  3/8” 

Washer

(1)  5/32” Hex Key

INSTALLATION INSTRUCTIONS

1.  Set coupler in place in the center of ceiling plate and slide ½”-13 X 4” hex head bolt through both parts

(see Figure 1). Secure using ½”-13 Nylock nut.

2.  Install two 3/8”-16 X 5/8” hex machine screws, with 3/8” washers, through adjusting slots on either side

of bracket into holes in the coupler assembly (see Figure 1). Do not tighten.

3.  Adjust coupler to desired angle and tighten two 3/8”-16 X 5/8” hex machine screws.

4.  Install extension pipe in coupler and secure using the 5/16”-18 X 3/8” set screw (see Figure 2).

Figure 1. Assembly

Figure 2. Assembly

5/16”-18 X 3/8”