background image

I N S T A L L A T I O N   I N S T R U C T I O N S

Instrucciones de instalación

Installationsanleitung

Instruções de Instalação

Istruzioni di installazione

Installatie-instructies

Instructions d´installation

Automated Quad Horizontal Door System

This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio or television
communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment and receiver

Connect the equipment to an outlet on a circuit other than that to which the receiver is connected

Consult the dealer or and experienced radio/TV technician for help

CM6QH SERIES

Summary of Contents for CM6QH SERIES

Page 1: ...le protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does caus...

Page 2: ...er s responsibility to make sure all components are properly assembled and installed using the instructions provided Read all instructions before using this furnishing DANGER TO REDUCE THE RISK OF ELECTRIC SHOCK ALWAYS unplug this furnishing from the electrical outlet before cleaning WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Unplug from outlet before putting on o...

Page 3: ...stop reverse run a few seconds and then stop again Auxiliary Controls There is an activator button located on the front of the motor box which will activate the doors Status Light The Status Light on the front of the Motor Box indicates the operating condition of the mechanism In normal operating conditions the status light will be solid green with the doors at rest and will blink a series of gree...

Page 4: ...the track First engage the guidewheel plate wheel into the track area built into the base Then tip the top of the door into the mechanism and engage the pendant bolts into the slots in the carriages After hanging the doors spin the locking nut on the pendant bolts up so that the nut is finger tight against the bottom of the carriage See figure 3 5 Repeat his procedure for the 2 Front doors using t...

Page 5: ...Installation Instructions CM6QH SERIES 5 Figure 2 ...

Page 6: ...CM6QH SERIES Installation Instructions 6 Figure 3 Figure 4 ...

Page 7: ... cord can be used to position the IR sensor in the cabinet near to the other remote controlled units For example near to the VCR or DVD player Install Light Dimmer Module Optional With the dimmer option installed cabinet lighting can be switched on or off or dimmed using the left buttons on the systems remote control To install the optional dimmer 1 Plug 115VAC lighting into the back of the Light ...

Page 8: ...front of the motor box for approxamatly 13 seconds and then release it when the Status Light flashes quickly red green red green red green Figure 10 The controller will then be in Learn Mode The door will move for 3 seconds stop for 10 seconds and when it starts moving again it will be in it s Learn Mode When put into Learn Mode the mechanism runs back and forth several times and measures it s env...

Page 9: ...ut 8 position RJ 45 modular phone jack Discrete control for use with 3rd party control Position 8 Open Position 7 Stop IR Receiver Eye input for Eubank Inc supplied external IR reciever only Position 6 V out Position 5 Vcc 5v Radio Power for external RF reciever only Position 4 24 VDC Sequence control for use with 3rd party control Position 3 Sequence Open Stop Close Stop Position 2 Common Discret...

Page 10: ...8 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 30I Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA Post Code 518112 P 86 755 8996 9226 8996 9236 8996 9220 F 86 755 8996 9217 8820 000021 2007 Chief Manufacturing www chiefmfg com 03 07 ...

Reviews: