Troubleshooting
King Edge Vac
6-20
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
The force required to move the upper spreader clamps along the linear rods is normally 2-5 pounds. If
there is extra tension on the belt, the movement may be erratic or slow. If the belt is too lose it may skip
on the pulley.
Flatwork Not Properly Spread
Message Reads:
UPPER SPREADER STALLED
1. Excessive tension in the
upper spreader belt.
Refer to the
REPAIR
chapter,
Spread
Section
section,
Upper Spreader Belt
Tension Adjustment
procedure.
•
2. Excessive friction in the
rail-carriage assembly.
Lubricate the rail. Refer to the
PRE-
VENTIVE MAINTENANCE
chapter,
Weekly PM
section,
Lubricate Upper
Spreader Rail
procedure.
•
3. Upper spreader encoder
(PX9) malfunction.
Check. Adjust/replace as necessary.
Refer to the
REPAIR
chapter,
Sensors
section,
Proximity Sensor Position-
ing Adjustment
procedure.
•
4. Home sensor (PX12) mal-
function.
Check. Adjust/replace as necessary.
Refer to the
REPAIR
chapter,
Sensors
section,
Proximity Sensor Position-
ing Adjustment
procedure.
•
5. Taut sensors (PE14 L/R)
malfunction.
Check. Adjust/replace as necessary.
Refer to the
REPAIR
chapter,
Sensors
section,
Taut Photosensor Alignment
procedure.
•
6. The inverter may need to
be adjusted.
Adjust the inverter. Contact the factory
Service Department.
•
7. Defective run relay (CR4)
or fuse.
Test and/or replace.
•
8. Spreader timing out of
adjustment.
Refer to the
CHI PANEL OPERATION
bulletin, spreader related
Adjustment
and
Testing
sections.
•
Upper Spreader Clamps Bang
or Drag at the Center of the
Unit
(continued on next page)
1. Upper spreader encoder
(PX9) out of adjustment/
malfunctioning.
Check. Adjust/replace as necessary.
Refer to the
REPAIR
chapter,
Sensors
section,
Proximity Sensor Position-
ing Adjustment
procedure.
•
2. Home sensor (PX12) out
of adjustment/malfunction-
ing.
Check. Adjust/replace as necessary.
Refer to the
REPAIR
chapter,
Sensors
section,
Proximity Sensor Position-
ing Adjustment
procedure.
•
6.7 Spread Section
TOC
INDEX
Summary of Contents for King Edge VAc
Page 12: ......
Page 40: ......
Page 54: ......
Page 78: ......
Page 250: ...3038 015e King Edge VAC PL 32 This page intentionally left blank TOC INDEX PL TOC...
Page 262: ...SC 2 460V Motor Circuit SC TOC TOC INDEX...
Page 264: ...SC 4 208 230V Motor Circuit SC TOC TOC INDEX...
Page 266: ...SC 6 Control Power Communications SC TOC TOC INDEX...
Page 268: ...SC 8 Controller Inputs SC TOC TOC INDEX...
Page 270: ...SC 10 Control Outputs SC TOC TOC INDEX...
Page 273: ...King Edge Vac 3210 437b SC 13 This page intentionally left blank SC TOC TOC INDEX...
Page 274: ...SC 14 Prefeeder Control Circuit SC TOC TOC INDEX...
Page 276: ...3210 437b King Edge Vac SC 16 This page intentionally left blank SC TOC TOC INDEX...
Page 277: ...SC 17 24 VAC Control Circuit SC TOC TOC INDEX...
Page 278: ...SC 18 Interlock Circuit system E stop SC TOC TOC INDEX...
Page 279: ...SC 19 Pneumatic Diagram SC TOC TOC INDEX...
Page 280: ...SC 20 Prefeeder Electrical Panel SC TOC TOC INDEX...
Page 282: ...SC 22 Disconnect Panel SC TOC TOC INDEX...
Page 284: ...SC 24 Main Eletrical Panel SC TOC TOC INDEX...
Page 285: ......
Page 286: ......
Page 287: ......
Page 288: ......
Page 290: ......
Page 292: ......
Page 302: ......