Press the ENTER button. The test function
menu displays.
The numbers in the display correspond to
the control output LEDs that trigger with
each operation. Each of the following sec-
tions has sample CHI Panel displays and
other information to use as a guide in run-
ning the test.
The control system automatically begins
to operate each of the components in-
volved in the test.
Look at the I/O modules to confirm the
correct LEDs light. If a component fails
to operate or an LED fails to trigger prop-
erly, refer to the
TROUBLESHOOTING
chapter for possible causes.
NOTE:
The numbers appearing
in the messages correspond
to hardware output LED’s. Use
the schematic diagrams as
a reference.
10.
11.
12.
End Testing
To leave test mode, follow these steps:
When finished running a test, press the
TEST button once to return to the SE-
LECT TEST menu.
Press the TEST button again to leave test
mode.
Press the red STOP button to shut down
the unit.
Turn OFF the compressed air supply to
the machine.
Turn power OFF at the main disconnect
switch.
Remove the interlock switch jumper.
Close and secure the right endframe
door.
WARNING
Never operate the unit unless
all safety covers are in place
and all safety equipment is
working correctly.
1.
2.
3.
4.
5.
6.
7.
TOC
INDEX
C-TOC
Summary of Contents for Edge MAXX
Page 1: ...EDGE MAXX Dual Input Large Piece Spreader Feeder INSTRUCTION MANUAL...
Page 12: ......
Page 102: ......
Page 132: ......
Page 196: ......
Page 228: ...3038 010k Edge Maxx PL 14 This page intentionally left blank TOC INDEX PL TOC...
Page 232: ...3038 010k Edge Maxx PL 18 This page intentionally left blank TOC INDEX PL TOC...
Page 250: ......
Page 252: ...SC 2 460V Motor Circuit TOC INDEX SC TOC...
Page 255: ...Edge Maxx 3210 393d SC 5 This page intentionally left blank TOC INDEX SC TOC...
Page 259: ...Edge Maxx 3210 393d SC 9 This page purposely left blank TOC INDEX SC TOC...
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 278: ......
Page 280: ......