3024-024e
Edge Maxx
C-14
Start Testing
To test any of the CHI Panel’s functions,
follow these first steps:
Locate the appropriate schematic(s).
Turn power OFF at the main disconnect
switch.
Open the right endframe door and locate
the I/O modules. During the test, the LED’s
will light to show the control signals.
WARNING
This safety interlock switch
is only to be defeated
temporarily while performing
this procedure. Never
operate the unit unless
all safety systems
are working correctly.
Serious Injury Could Result.
The unit will not operate while a safety
interlock switch is open. As a temporary
measure during this procedure, defeat the
door interlock switch by inserting one
of the switch keys that shipped with the
unit.
Perform only when the unit is
RUNNING.
Use extreme caution.
Make sure the compressed air supply to
the unit is ON.
Turn power ON at the main disconnect
switch and start the unit.
Test mode can only be entered if the
spread/feed system is off. Make sure no
STATION button is lit and the CHI Panel
display reads:
FEEDER OFF
1.
2.
3.
4.
5.
6.
7.
Press and hold the TEST button; then,
press the ENTER button. Release both
buttons. The SELECT TEST menu dis-
plays as follows:
SELECT TEST
IN12 TR12 SPR12 IRN SENSE
The flashing cursor is under the 1 of
IN12.
Press the CURSOR button until the flash-
ing cursor is under the desired adjustment
area:
IN1 is used to test the left inlet station.
See
Inlet Section Tests
.
IN2 is used to test the right inlet station.
See
Inlet Section Test
.
TRN1 is used to test the left station
transfer system. See
Transfer Section
Tests
.
TRN2 is used to test the right station
transfer system. See
Transfer Section
Tests
.
SPR12 is used to test the upper and
lower spreader systems. See
Spreader
Section Tests
.
IRN has no associated tests and appears
for display purposes only.
SENSE is the sensor activation test and
it used to check general sensor func-
tion, specific function and to properly
setup replacement sensors. See
Sensor
Tests
.
8.
9.
•
•
•
•
•
•
•
TOC
INDEX
C-TOC
Summary of Contents for Edge MAXX
Page 1: ...EDGE MAXX Dual Input Large Piece Spreader Feeder INSTRUCTION MANUAL...
Page 12: ......
Page 102: ......
Page 132: ......
Page 196: ......
Page 228: ...3038 010k Edge Maxx PL 14 This page intentionally left blank TOC INDEX PL TOC...
Page 232: ...3038 010k Edge Maxx PL 18 This page intentionally left blank TOC INDEX PL TOC...
Page 250: ......
Page 252: ...SC 2 460V Motor Circuit TOC INDEX SC TOC...
Page 255: ...Edge Maxx 3210 393d SC 5 This page intentionally left blank TOC INDEX SC TOC...
Page 259: ...Edge Maxx 3210 393d SC 9 This page purposely left blank TOC INDEX SC TOC...
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 278: ......
Page 280: ......