Ironer Speed Interlock Adjustments
[IRONER]
All of these settings deal with how the
spreader/feeder interacts with other machines in
the line from the viewpoint of speed control.
Settings include:
The unit’s minimum and maximum
speeds.
The distance traveled by the flatwork
between each ironer encoder pulse.
The feeder speed relative to the ironer.
How machine speed is controlled.
When [IRONER] is selected from the SELECT
ADJUSTMENT menu, the following displays:
IRON 028-180FPM 0.26IPP
FEEDER 90PERCENT PWM=0
•
•
•
•
IRON is actually two settings. The first number
set (3 digits after the word IRON), controls
the minimum speed at which the feeder can
operate.
The second set of IRON digits controls
the maximum speed at which the feeder can
operate. Combined together they set the min/max
operating range of the unit in feet per minute.
Also, notice that PWM has 3 possible settings.
Setting 0 allows the unit to operate in AUTO
mode with its speed controlled by the Chicago
®
ironer behind it.
Setting 1 allows the unit to operate in manual,
controlling its own speed. Setting 2 is no longer
used.
Refer to the table below for more information
about each available function to use as a guide
in making adjustments.
IRONER SPEED INTERLOCK ADJUSTMENT (IRN)
Adjustment Function
Range
(Increment)
Low Range
Select
High Range Select
Standard
Setting
IRON*
Sets the speed range of the
feeder discharge, in feet per
minute.
Minimum
000-048FPM
(4 FPM)
Laydown is
erratic.
Laydown is erratic.
28FPM
Maximum
052 - 180 FPM
(4 FPM)
152FPM
IPP*
Distance, in inches, flatwork
travels per pulse from the
ironer speed signal or
encoder.
.10” - 1.90”
(.02”)
Auto speed
erratic.
Auto speed erratic.
0.26 for encoder
1.00 for Century
1.84 for Imperial/
TriStar
FEEDER
PERCENT*
Determines the difference in
speed between the feeder to
the ironer.
70 - 98%
(2%)
Excessive pull
on flatwork
leads to
distortion.
Flatwork is crushed
in accordion
fashion.
98%
PWM
Determines source of the
controlling speed signal.
0 = Input - Feeder follows ironer speed (Auto).
1 = PWM - Feeder sets own speed (manual).
2 = Not used
0
* Only active when PWM=0. These parameters adjust the feeder speed automatically according to the ironer’s speed
signal or encoder.
TOC
INDEX
C-TOC
Summary of Contents for Edge MAXX
Page 1: ...EDGE MAXX Dual Input Large Piece Spreader Feeder INSTRUCTION MANUAL...
Page 12: ......
Page 102: ......
Page 132: ......
Page 196: ......
Page 228: ...3038 010k Edge Maxx PL 14 This page intentionally left blank TOC INDEX PL TOC...
Page 232: ...3038 010k Edge Maxx PL 18 This page intentionally left blank TOC INDEX PL TOC...
Page 250: ......
Page 252: ...SC 2 460V Motor Circuit TOC INDEX SC TOC...
Page 255: ...Edge Maxx 3210 393d SC 5 This page intentionally left blank TOC INDEX SC TOC...
Page 259: ...Edge Maxx 3210 393d SC 9 This page purposely left blank TOC INDEX SC TOC...
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 278: ......
Page 280: ......