Troubleshooting
Edge MAXX
6-22
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
Excessive Pull to One Side
1. Black lower spreader belt
gap needs adjustment.
Adjust. Refer to the
REPAIR
chap-
ter,
Spread Section
section,
Lower
Spreader Belt Gap Adjustment
procedure.
•
2. The lower spreader belt
speed may need to be
adjusted.
Adjust LOWSPRED setting. Refer to
the
CHI PANEL OPERATION
bulletin,
Adjustment
section,
Program Adjust-
ments (CHI)
procedure.
•
3. A defective solenoid, regu-
lator, or cylinder is causing
the spreader clamps to
open at different speeds.
Test and replace the defective compo-
nent.
•
TOC
INDEX
Summary of Contents for Edge MAXX
Page 1: ...EDGE MAXX Dual Input Large Piece Spreader Feeder INSTRUCTION MANUAL...
Page 12: ......
Page 102: ......
Page 132: ......
Page 196: ......
Page 228: ...3038 010k Edge Maxx PL 14 This page intentionally left blank TOC INDEX PL TOC...
Page 232: ...3038 010k Edge Maxx PL 18 This page intentionally left blank TOC INDEX PL TOC...
Page 250: ......
Page 252: ...SC 2 460V Motor Circuit TOC INDEX SC TOC...
Page 255: ...Edge Maxx 3210 393d SC 5 This page intentionally left blank TOC INDEX SC TOC...
Page 259: ...Edge Maxx 3210 393d SC 9 This page purposely left blank TOC INDEX SC TOC...
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 278: ......
Page 280: ......