Edge MAXX
Troubleshooting
6-13
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
CAUSE
SOLUTION
Noisy Operation
1. Mechanical components
need lubrication.
Lubricate. Refer to the
PREVENTIVE
MAINTENANCE
chapter,
Semi-An-
nual PM
section,
Grease Bearings
procedure.
•
2. Inverter frequency setting
is causing noisy motor
operation.
Adjust frequency. For more informa-
tion, contact the factory service depart-
ment.
•
Ribbon Set Not Working
1. Improper tension on rib-
bons.
Adjust. Refer to the
REPAIR
chap-
ter, and the appropriate section and
procedure.
•
2. Ribbon drive roll tracking
tape worn smooth.
Adjust. Refer to the
REPAIR
chap-
ter, and the appropriate section and
procedure.
•
3. Inverter or motor protector
fault.
Refer to
Electrical
section problems,
Circuit Breaker/Motor/nverter Fault
.
•
Rotating Elements Stop
1. Drive belt or chain is slip-
ping or broken.
Adjust tension or replace if broken,
worn, or frayed.
•
2. Idler pulley loose or fro-
zen.
Adjust tension or replace.
•
3. If one rotating element
is stationary, check for a
broken shaft, bad bearing
or a loose or worn drive
sprocket.
Replace as necessary.
•
4. Check CHI Panel for message and locate appropriate solution within
this chapter.
Machine Operation is Sluggish
Message reads:
AIR PRESSURE IS LO
1. Incoming air pressure is
below 60 psi (415 kPa).
Make sure air supply to feeder is ON
and supply hose is not obstructed or
loose.
Make sure air supply to feeder is at
least 80 psi (550 kPa).
Make sure air filter is clean. Refer to
the
PREVENTIVE MAINTENANCE
chapter,
Semi-Annual PM
section,
Clean Air Filter/Regulator/Auto
Drain
procedure.
•
•
•
6.4 Mechanical
TOC
INDEX
Summary of Contents for Edge MAXX
Page 1: ...EDGE MAXX Dual Input Large Piece Spreader Feeder INSTRUCTION MANUAL...
Page 12: ......
Page 102: ......
Page 132: ......
Page 196: ......
Page 228: ...3038 010k Edge Maxx PL 14 This page intentionally left blank TOC INDEX PL TOC...
Page 232: ...3038 010k Edge Maxx PL 18 This page intentionally left blank TOC INDEX PL TOC...
Page 250: ......
Page 252: ...SC 2 460V Motor Circuit TOC INDEX SC TOC...
Page 255: ...Edge Maxx 3210 393d SC 5 This page intentionally left blank TOC INDEX SC TOC...
Page 259: ...Edge Maxx 3210 393d SC 9 This page purposely left blank TOC INDEX SC TOC...
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 278: ......
Page 280: ......