Mymesh Product Sheet

Connect any light, anywhere.

MYMESH-COPD17M

IP66 Rated Compact Passive Infra Red (PIR) 

Occupancy Detector & Photocell

(Input: 100-240 Vac  50/60Hz) 

This MYMESH-COPD17M Lighting Control has an IP66 
rated weatherproof enclosure and can be surface 
mounted onto an external wall. Confi gurable for any 
room occupancy style, via the Mymesh App.

Installation:

Please read these instructions before installing the 
product.
NOTE: MYMESH-COPD17M is compatible with Mymesh 
commissioning tools. 
To be installed by a competent person with reference 
to BS 7671 or equivalent local standards. If in doubt 
consult a qualifi ed electrician.
•  Plan where the MYMESH-COPD17M is to be located 

(see diagram 1). Switch off  supply and check for 
hidden cables and pipes. 

•  The detector should be sited so that it is not shaded 

from daylight.

•  Make sure the power is isolated from the circuit.
•  Remove the front cover by by removing the two 

screws on the front face of the product.

•  The detector should be mounted between 1 and 2.2 

metres high, via any of the four pre-drilled mounting 
holes only and must be mounted with the cable 
entering from below. 

•  Thread mains cable carefully through the required 

membrane entry point.

•  The MYMESH-COPD17M should be connected as 

shown in diagram 2:

  L - Live in.   N - Neutral in.
•  Replace the front cover ensuring the two screws are 

secured.

Operation:

To check the operation of the MYMESH-COPD17M:
•  Turn on the supply then after 20 seconds if the sensor 

has recognised movement of a person within its 
zone of detection the integral red LED on MYMESH-
COPD17M will stay illuminated for 4 seconds before 
the red LED turns off .

•  Thereafter, every time movement is detected by 

MYMESH-COPD17M the integral red LED will stay 
illuminated for 4 seconds. 

The control also features adjustable time out (time 
lag) control and daylight threshold control which are 
confi gured by the Mymesh App.

Precautions:

•  Do not place the MYMESH-COPD17M near heat 

sources, fans or in ventilated ceiling voids.

•  MYMESH-COPD17M can be wired in parallel (sharing 

the same Live and Neutral).

•  Do not place close to, or positioned such 

that, any light source points directly into the 
MYMESH-COPD17M. 

•  Ensure wires and cables are securely held within the 

connection terminals.

•  The MYMESH-COPD17M should be protected by a 5 

or 6 Ampere mcb or fuse.

•  Disconnect the MYMESH-COPD17M from the circuit 

before performing insulation testing of the wiring 
circuit.

Status LED blinking sequence:

Normal:   

 

Both LED’s off .

Identifi cation of device: 

Red LED blinks.

16/04/20 

DAT0071 MYMESH-COPD17M  (Issue 01)