Supported Command Classes
Command Class
Version
Non-Secure CC
Secure CC
BASIC
2
x
ZWAVEPLUS_INFO
2
x
ASSOCIATION
2
x
MULTI_CHANNEL_ASSOCIATION
3
x
ASSOCIATION_GRP_INFO
3
x
TRANSPORT_SERVICE
2
x
VERSION
3
x
MANUFACTURER_SPECIFIC
2
x
DEVICE_RESET_LOCALLY
1
x
INDICATOR
3
x
POWERLEVEL
1
x
SECURITY_2
1
x
SUPERVISION
1
x
FIRMWARE_UPDATE_MD
5
x
APPLICATION_STATUS
1
x
CONFIGURATION_V4
4
x
SWITCH_BINARY
2
x
CENTRAL_SCENE
3
x
Supporting Command Class Basic
The basic command classes are mapped into the Switch Binary Command Class.
Basic Command received
Mapped Command (Binary Switch)
Basic Set (0xFF)
Switch Binary Set (0xFF)
Basic Set (0x00)
Switch Binary Set (0x00)
Basic GET
Basic Report 0x00 if the Binary Switch is in Off state 0x00
Basic Report 0xFF if the Binary Switch is in On state 0xFF
Supporting Command Class Indicator
The device supports the Command Class Indicator V3 (ID 0x50). When the device receives an indicator set, the led blinks
accordingly to the Indicator set received.
The color shown by the indicator will be:
RED
: if
the device is included without Security
BLUE
:
if the device is included in S2 Unauthenticated Mode
GREEN
: