60
After having memorized the limit switches, perform the following command sequence:
At the end of the sequence, wait until the rolling shutter is completely lowered. From this
moment onwards the motor moves in “Dead Man” mode. This enables the regulation of
the positions to be adjusted precisely.
Carry out the following operations:
• Lower the rolling shutter until the adjustable slats are completely opened;
• If you wish, raise the rolling shutter until it reaches an intermediate opening of the slats
(preferred opening position);
• Press button B on the remote control for 2 seconds: the rolling shutter will move in
sequence to the memorised positions: closed, maximum opening, preferred opening.
Functions of the remote control*
Type of Command
Outside of tilting area
In tilting area
A short (< 2 sec)
Completely raised
Less light
C short (< 2 sec)
Completely lowered
More light
A long (> 2 sec)
-
Out of tilting area
Completely raised
C long (> 2 sec)
-
Out of tilting area
Completely lowered
B long (> 2 sec)
Entry in tilting area
-
B short (< 2 sec)
Stops the motor
-
B long (> 2 sec)
-
Confirmation of the new
preferred opening position
* see key to symbols and operational notes
REMO
TE CONTROL PROGR.
E N G L I S H
2 sec
+
B
C
+
B
C
B
SLAT TILTING MECHANISM SETTING
MODE 2
:
Orientable roller shutter without coupling point with tilting
function adjustable below the lower limit.
Only for roller shutter type Solomatic.
Not suitable for centralised control units. Not available on motors Ø 35.