SENSOR TEST OPERATION
When the sensor has detected its rest position and then memorised the angle of
inclination for the “static load” function (if enabled), it will run in test mode for the first
three minutes of operation: in case of alarm the awning will close but without application
of the eight-minute period when reopening is disabled, which is what occurs in normal
operational mode.
During these 3 minutes it is necessary to:
- Verify the alarm threshold for wind caused vibrations;
- Check the “Static Load” alarm threshold;
- Verify the absence of alarms when opening the awning.
VERIFY WIND ALARM THRESHOLD
Open the awning completely. Apply a vibration to the end bar, gradually increasing its
amplitude, until the motor closes the awning.
If the awning closes even with slight vibrations, then the threshold set is too low.
If the awning does not close, even when applying large amplitude vibrations, then the
threshold set is too high, or there is a malfunction in the radio communications between
the sensor and the motor.
Whilst the awning is closing, it is possible to use the remote control to stop it and open
it back again.
Note: to properly check the wind alarm threshold, the vibrations have to be applied
constantly for at least 5 seconds.
VERIFY STATIC LOAD ALARM THRESHOLD (if enabled)
Open the awning completely. Apply a load that lowers the end bar over the limit set
during the activation procedure.
If the awning closes even with slight load, then the threshold was not memorized
properly. If the awning does not close, then a sufficient load was not applied, or there is a
malfunction in the radio communications between the sensor and the motor.
21
The angle of the shift
must be greater than 2
degrees as compared to
the rest position.
- After the motor makes its confirmation movements, the sensor will wait in stand-by to
memorise the inclination angle.
- Within one minute manually incline the awning down to its limit for al least 2 seconds
and then bring it back to its rest position.
- If the position was memorised properly, the motor will make its confirmation movements.
> 2°
Within three minutes proceed with the SENSOR TEST OPERATION.
*
E
NG
L
IS
H