- Snap the shell onto the base.
- Stand by for 10 seconds until the sensor detects the rest position and the motor makes
its confirmation movements*.
Within three minutes proceed with the SENSOR TEST OPERATION.
Before assembling the shell on the base:
- Rotate the selector to a middle value from 1
to 9 (e.g. 5).
- Activate the sensor by pressing the SET
button for at least 4 seconds until the LED
flashes twice quickly.
SENSOR ACTIVATION
“STATIC LOAD” FUNCTION ACTIVATION/DEACTIVATION
2
4 sec
set
5
SELECTOR
You have 10 seconds to check and change the function status as required.
LED OFF = function not active
LED ON = function active
To change the function status, press the SET button briefly.
4
PROCEDURE WITHOUT ACTIVATION “STATIC LOAD” FUNCTION (LED OFF)
20
4
PROCEDURE WITH ACTIVATION “STATIC LOAD” FUNCTION (LED ON)
- Snap the shell onto the base.
- Stand by for 10 seconds until the sensor detects the rest position and the motor makes
its confirmation movements*.
10 sec.
........
set
set
*Note:
for Wave RX motors
manufactured before 01/2013 and
TDS Gold control units manufactured
before 04/2013 the procedure ends
without
confirmation movements.
*
10 sec.
........
*Note:
for Wave RX motors
manufactured before 01/2013 and
TDS Gold control units manufactured
before 04/2013 the procedure ends
without
confirmation movements.
To change the previously memorised
angle of inclination, the function must
be deactivated and then reactivated as
follows: LED ON - OFF - ON.
*
E
NG