TECHNICAL SPECIFICATIONS
SAFETY INFORMATION
Power supply
110 - 230 VAC ± 10% 50/60 Hz
Maximum Load
1200 Watt
System temperature limitation 105 °C
Work temperature
From -10° to 40° C
Power consumption
< 230 mW in standby mode
< 500 mW when motor is moving
Radio frequency
868.4 MHz
Protection system
S2 Security
Maximum distance
Up to 100 m outdoor
Up to 40 m indoor
Dimensions
37x37x17 mm
Actuator element
Relay
Compliance
CE, RoHs
Electrical IP Rating
IP20
5
INFO:
The device is designed to be installed in flush mounting junction boxes or
close to the motor to be controlled.
WARNING:
The device must be installed by electricians qualified to intervene
on electrical systems in compliance with safety requirements set out by the
regulations in force.
DANGER:
The device must be connected with a voltage of 230 VAC, before
carrying out any operation, please make sure the power main switch is in OFF
position.
DANGER:
Any procedure requiring the use of the Integrated Button is related
only to the installation phase and is to be considered a service procedure that
must be performed by qualified personnel. This operation must be performed
with all necessary precautions for operating in areas with a single level of
insulation.
WARNING:
Do not connect loads that exceed the maximum load permitted by
the actuator element.
WARNING:
All connections must be performed according to the electrical
diagrams provided.
WARNING:
The device must be installed in norm-compliant systems suitably
protected from overloads and short circuits.
E
NG
L
IS
H