19
IT
ALIANO
Parameter
Number
Size
Parameter
Name
Default
Value
Description
25
1
FINE_
CALIBRA-
TION
100
Adjustment in Percentage value of the
50% level position after the initial ca-
libration. Increasing/decreasing of this
value will move the 50% level in the UP
direction/Down direction,
Parameters Values Min: 90 Max: 110
Value
Description
90-110
Expressed in percentage
Parameter
Number
Size
Parameter
Name
Default
Value
Description
37
4
REPORT_
FREQUENCY
5
Time in seconds after which the new po-
sition report is sent if the target position
is not reached. When the target position
has been reached a final position report
is sent.
Parameters Values Min: 1 Max: 100
Value
Description
1-100
Time expressed in second
Parameter
Number
Size
Parameter
Name
Default
Value
Description
38
4
SEND_
MULTILE-
VEL_
REPORT
0
Define if the Multilevel Report will be
sent unsolicited.
Parameters Values Min: 0 Max: 1
Value
Description
0
Only Windom Covering report will be sent
1
Both WiDom Covering and Multilevel Report will be sent
Report Configuration
E
NG
L
IS
H