18
Parameter
Number
Size
Parameter
Name
Default
Value
Description
22
4
MIN_
LEVEL_
TIME
100
Time to reach Min level starting from the
Max Level.
Defines the time thousandth of a second
necessary to reach the complete close
position starting from complete open
position.
Parameters Values Min: 100 Max: 100.000
Value
Description
100-100.000 Time expressed in thousandths of a second
Parameter
Number
Size
Parameter
Name
Default
Value
Description
23
4
INVERTION_
TIMEOUT
1000
Time in thousandth of a second after
which the movement direction can be
changed.
Parameters Values Min: 1000 Max: 10.000
Value
Description
1000-10.000 Time expressed in thousandths of a second
Parameter
Number
Size
Parameter
Name
Default
Value
Description
24
4
LIMIT_
SWITCH_
TIMEOUT
3000
Time in thousandth of a second for
recognizing that the limit switch has
been reached.
Parameters Values Min: 1000 Max: 10.000
Value
Description
1000-10.000 Time expressed in thousandths of a second
E