15
OFFLINE SETUP MODE
The device has a unique feature that allows to configure some parameters without using
any user interface. This feature enables the professional user to setup the main features
of the device in the field even if the device is not included in a Z-Wave
TM
Network. When
the device will be included in the network all these configuration parameters will be
maintained.
To enter in offline setup mode, operate 2 clicks on the integrated button.
When the device is in Offline setup mode the led becomes solid Blue and the following
configurations are permitted:
1 click
Invert the movement of the motor. Equivalent to set parameter
n. 61 to 1.
2 clicks
Reset calibration. Equivalent to set parameter n. 20 to 0.
3 clicks
This configuration will apply only if the calibration is completed.
Set “ON-OFF favorite Level”. The current level will be set as ON_
FAVORITE_LEVEL if the current level is greater than 49 or will be
set to OFF_FAVORITE_LEVEL if the current level is smaller than 50.
If you want to set both ON and Off favorite Level you have to carry
on this setup two times:
One time for the ON position by moving the motor in the chosen
ON_FAVORITE_LEVEL; and a second time for the chosen OFF_
FAVORITE_LEVEL.
After receiving the command the led blinks a number of times equal to the number of
clicks recognized.
6 clicks
Exit from Offline setup mode and return to normal operation.
Hold down for 5
seconds
Reset all configuration parameters to their default value and
return to normal operation.
After entering in Offline setup mode, the device returns to normal operation if no action
on the switch is detected for more than 20 Seconds.