Lamp Replacement
The Rogue Outcast 1 Hybrid is equipped with an USHIO NSL 400-W lamp. Follow the procedure below to
safely change the lamp,
Procedure
1.
Turn the product off and disconnect it from power. Wait at least 15 minutes for the lamp to cool down.
2.
Remove both head covers by removing 8 Phillips-head ¼-turn screws.
3.
Orient the bottom of the moving head so that the fan is facing downward.
4.
Remove the 2 wires connected to the lamp by the spade terminals.Using the lamp base, push the
lamp to the left against the spring clips located on the left.
5.
Roll the lamp out the top and pull it away.
6.
Reverse the steps above to install the new lamp. Do not touch the glass with bare hands.
Increasing the Lamp’s Life
•
ALWAYS turn the lamp off by using the DMX controller or the product’s control panel, then wait at
least 5 minutes before switching off the product. This will keep the fans running to extract any
remaining heat from the product’s head.
•
DO NOT power cycle the product unless it is necessary.
•
DO NOT re-strike the lamp immediately after turning it off. Chauvet recommends waiting
5 minutes before trying to re-strike the lamp.
•
DO NOT touch the lamp without wearing gloves to avoid leaving grease on the bulb or on the
contacts that could reduce the lamp’s life.
•
ALWAYS change the lamp when it has reached its recommended lifespan to avoid the risk of lamp
explosion.
Disconnect the product from power before opening.
Do not turn product on without a lamp!
!
!