Page 7 of 29
Rogue Outcast 1 Beam User Manual Rev. 1
S
ETUP
3. Setup
AC Power
Each Rogue Outcast 1 Beam has an auto-ranging power supply that works with an input voltage range of
100 to 240 VAC, 50/60 Hz. To determine the power requirements for each Rogue Outcast 1 Beam, refer to
the label affixed to the product. You can also refer to the
chart in this manual.
The listed current rating indicates the maximum current draw during normal operation. For more
information, download Sizing Circuit Breakers from the Chauvet website:
AC Plug
The Rogue Outcast 1 Beam comes with a power input cord terminated with a Seetronic Powerkon IP65
connector on one end and an Edison plug on the other end (U.S. market). If the power input cord that came
with the product has no plug, or if the plug needs to be changed, use the table below to wire the new plug.
Fuse Replacement
1.
Disconnect this product from the power outlet.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove the blown fuse and replace with another fuse of the same type and rating (T 5 A, 250 V).
4.
Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Rogue Outcast 1 Beam can be linked to a DMX controller using a 5-pin DMX connection. If using other
DMX-compatible products with this product, each can be controlled individually with a single DMX controller.
DMX Personalities
The Rogue Outcast 1 Beam uses a 5-pin DMX data connection for the 20- and 25-channel DMX personalities.
•
Refer to the
for a brief description of each DMX personality.
•
Refer to the
chapter to learn how to configure the Rogue Outcast 1 Beam to work in
these personalities.
•
The
DMX Values
section provides detailed information regarding the DMX personalities.
Remote Device Management (RDM)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate
bi-directionally along existing DMX cabling. Check the DMX controller’s User Manual or with the
manufacturer, as not all DMX controllers have this capability. The Rogue Outcast 1 Beam supports RDM
protocol that allows feedback to make changes to menu map options.
•
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure
the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
•
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
Make sure to disconnect the product’s power cord before replacing a blown fuse.
Always replace the blown fuse with another of the same type and rating.
!
!