14
LT5049 (ISS 2)
SECTION FIVE Specification (installation instructions)
NOTE! Low Lintel version fire box height is 497mm (551mm standard P2000+)
NATURAL GAS
PROPANE GAS
Category of Appliance:
B
AS
B
AS
Category
I
2H
I
3P
Gas type:
G20
G31
Gas Pressure:
20 mbar
37 mbar
Gas input high:
7.00 kW Gross
7.00 kW Gross
Gas input low:
2.40 kW Gross
2.40 kW Gross
Injector Main:
Size 460
Size 135
Data Label Location: Frame of appliance on top RH corner behind trim (2000 Plus)
Lower L/H Flange of Appliance (2000 Plus Lo Lintle)
Gas Connection:
8 mm OD Tube
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009 and the result is 55.6% The gross calorific value of the
fuel has been used for this efficiency calculation. GASTEC have certified the test data from which it has been calculated. The efficiency value
may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
Summary of Contents for PARAGON 2000 Plus Low Lintel SLIDE CONTROL
Page 27: ...www charltonandjenrick co uk 27 LT5049 ISS 2 ...
Page 28: ...28 LT5049 ISS 2 ...