CT500-6 operation
The CT500-6 is fully automatic once installed properly. The LED
indicator lights inform the user of the progress of the charging
cycle and confirm proper connections.
CT500-6 LED indicators
The dual color charging mode light indicates the state of charge
of the battery. The light will illuminate only when the charger is
properly connected to the battery and AC power is applied. Red
indicates bulk charging, flashing red/green indicates absorbtion
or topping off, while green indicates the battery is fully charged.
Please review the table below for electrical specifications.
Please read the entire installation manual
before installing the battery charger. If there
are any questions or concerns, please email
us or call our toll-free number given below.
The CT500-6 UL/CSA 1236 certified battery
charger is totally waterproof and precisely
regulated. It is designed to be portable or
permanently mounted on almost any type
of vehicle including generators, ATVs, RVs,
lawn and garden tractors, snowmobiles,
motorcycles, and personal watercraft. This
product line is particularly suited for storage,
security, standby and remote applications.
The charger can be left connected to the bat-
tery indefinitely.
The CT500-6 is a three stage charger that
ensures that the battery is recharged with
precision and will be restored to its full ca
-
pacity as fast as possible while prolonging
its life. The charger is rugged, reliable and
completely automatic.
CT500-6
Installation Manual
5/12/14 Ver. A
PARAMETER DESCRIPTION / CONDITIONS
MIN
NOM
MAX UNITS
V
FSTERM
Fast charge voltage, 25C
14.4
14.5
14.6
VDC
V
FLOAT
Float voltage, I
OUT
< 1.0 A, 25 C
13.4
13.5
13.6
VDC
I
FS
Fast charge, V
BATTERY
= 12V
5.0
5.2
5.4
Amps
I
FLTERM
Float charge termination current
0.8
1.2
1.5
Amps
V
AC
RMS AC voltage range
180
240
264
VAC
I
SBY
Standby current, AC off
0.5
ma
Outline and mounting
LIMITED WARRANTY
For two years from date of purchase, Chargetek Inc. will
at its discretion repair or replace for the original consumer,
free of charge, any part or parts found to be defective by
Chargetek in workmanship or material. All shipping charges
under this warranty must be paid by the consumer. Proof
of purchase is required.
There is no other expressed warranty. Implied warranties,
including those of merchantability and fitness for a particular
purpose are limited to two years from the date of purchase.
This is the exclusive remedy and consequential damages
are excluded where permitted by law.
The CT500-6 must be connected to the battery in order for the
LEDs to illuminate. Should no illumination appear, unplug the
unit and recheck battery connections to ensure proper polarity.
The red wire connects to the positive and the black to the nega
-
tive battery terminal.
If the charger is left for extended periods of time, it is advisable
to check to be certain that the green light is on and the battery
voltage is less than 27.2VDC.
Over temperature: The CT500-6 will reduce its charging current
as its case temperature increases to insure proper operation.
In the event of a charger over temperature, the unit will turn off
until it cools and then restart automatically.
Over voltage protection (OVP): If the red light marked “Service”
ever illuminates, the unit should be removed and returned to
the factory. This light indicates that the internal over-voltage
protection shut off has been tripped and the unit will shut down.
6.000
3.170
5.250
.21 x 2
.21 x 2
.44 x 2
1.750
6.000
2.580
.160
4.544
DC Output
Cord
AC Input
Cord
3.170
2.580
2.764
1.590
Dimensions in inches