Charder MS5710 User Manual Download Page 1

MS5710 / 5711 / 5712

 

Medical Scale 

USER MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please keep the instruction manual at hand all the time for future reference.

 

Summary of Contents for MS5710

Page 1: ...0 MS5710 5711 5712 Medical Scale USER MANUAL Please keep the instruction manual at hand all the time for future reference...

Page 2: ...MC GUIDANCE AND MANUFACTURER S DECLARATION 9 SPECIFICATION 14 PANEL 16 KEY FUNCTION 17 POWER ADAPTOR STANDARDS 18 LCD DISPLAY SYMBOLS 19 USING SCALE 20 USING HOLD FUNCTION 20 USING TARE FUNCTION 22 US...

Page 3: ...rating Instructions They contain important instructions for installation proper use and maintenance of the device The manufacturer shall not be liable for damages arising out of failure to heed the fo...

Page 4: ...te batteries The optimum operating temperature for the scale is 5 to 35 although it will operate at higher and lower temperatures the scales battery life will be adversely effected CLEANING We would r...

Page 5: ...eep twice to indicate a stable weight value your reading should be taken at this point WARRANTY LIABILITY If a fault or defect is present on receipt of the unit which is within CHARDER MEDICAL s scope...

Page 6: ...y the owner or third parties natural wear changes or modifications incorrect or negligent handling overuse chemical electrochemical or electrical interference or humidity unless this is attributable t...

Page 7: ...ual warranty this means that the unit supplied will be free of faults for the length of the warranty period DISPOSING OF THE SCALE This product is not to be treated as regular household waste but shou...

Page 8: ...vice applied at the device Number as an example Please note the accompanying documents or Observe operating instructions Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan...

Page 9: ...communal collection points Carefully read this operation manual before setup and commissioning even if you are already familiar with Charder scales Transport and storage temperature limit indicating...

Page 10: ...emissions CISPR 11 Group 1 The MEDICAL SCALE MS5710 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electr...

Page 11: ...applicable Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1kV line s to line s 2kV line s to earth 1kV differential mode Not applicable Mains po...

Page 12: ...710 should assure that is used in such and environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 3 Vrms 150 KHz to 80 MHz 3 Vr...

Page 13: ...transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accurac...

Page 14: ...frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2...

Page 15: ...ificate Medical device Class III CE LCD Display 1 0 inch LCD display with 5 and 1 2 digits Dimension 360 410 120mm Key Functions ON OFF zero HOLD BMI TARE ON OFF UNIT HOLD BMI TARE Operating Temp and...

Page 16: ...15 Adaptor type 12V...

Page 17: ...16 PANEL MS 5710 MS 5711 MS5712...

Page 18: ...F the scale Determine Body Mass Index To hold weighing result on the display determine stable weighing value Selecting measuring units between kg or lb Tare weight during weighing process To reset the...

Page 19: ...18 POWER ADAPTOR STANDARDS CAUTION The device is only compatible with restricted power adaptors in dashed block below...

Page 20: ...the weight is stable Minor weight Weight under zero Zero symbols Weight is at zero point Low battery Battery need to charge or replaced Stable symbol Minor weight Zero symbol Low Battery kg BMI Indic...

Page 21: ...ilizes and stable sign shows on the screen Direction If a person is heavier than the scale capacity the display will show the Err prompt overload USING HOLD FUNCTION MS 5710 and MS 5711 MS5712 are pro...

Page 22: ...fluctuating weight values and then calculates average weight and displays the result on the screen Remove the object person from the scale platform The object person s weight reading will remain on th...

Page 23: ...t thus giving the true weight of the product person being tested Place the object need to be tare on the tread platform Press key after the weight stabilizes and stable sign displays Place the object...

Page 24: ...eters MS 5710 5711 5712 1 Turn on the scale using key 2 Proceed to weigh as normal 3 After the weight is stable and stable sign displays on the screen long press key for 3 seconds 4 Display will chang...

Page 25: ...normal mode 9 Use or to reset the display to 0 0kg Zero the scale Body Mass Index Categories Classification of weight for adults over 18 years on the basis of Body Mass Index according to WHO 2000 EK...

Page 26: ...play successively AUTO OFF TIME SETUP This enables operator to select the auto turn OFF time of the device BUZZER ON OFF SETUP This enables operator to select beep sound ON OFF Auto off time 120 sec 1...

Page 27: ...results can be printed out for records using RS232 interface cable included in accessory kit which is connected with the round plug at the back terminal The format presented below is the standard form...

Page 28: ...5712 can be connected to PC to transfer the weighing results 1 Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal PIN 2 TXD P...

Page 29: ...1 and Flow control at Hardware Then click OK to complete your setting 5 Output Data When the patient has been weighed and BMI calculated simply press the PRINT key to output data from scale to PC or...

Page 30: ...Adjustable feet M6 15 2 2 Spacer 6 6 13 2 3 Fixed plate top SS 4961 1 4 Fixed plate bottom SS 4971 1 5 Tapping Screw M3 10 3 6 User manual IN 1159 1 7 RS232 cable WR 2781 1 8 12V Adaptor 1 9 Plastic...

Page 31: ...disconnect the adaptor from main power supply before taking out the AC adaptor pin from indicator INSTRUCTION FOR CHARGING AND CONNECTING If prompt displays on the LCD please charge the scale with MS...

Page 32: ...ION FOR REPLACING BATTERIES 1 Removing the battery cover 2 Take the battery housing out 3 Replacing new batteries 4 Batteries are well installed 5 Installing the battery housing 6 Reinstalling the bat...

Page 33: ...32 ERROR MESSAGE...

Page 34: ...ective functionality or cause of damage covered by the warranty 2 Parts replacement from the manufacturing factory under the warranty or at a certain cost for the replaced parts plus the workmanship c...

Page 35: ...ects within weighing area The weighing scale is not put in a solid firm ground area such as carpet floor or lawn 3 Connection failure for data transmission to PC or printer Wrong connection wires or f...

Page 36: ...en loosed welding Unable to save or read data IC or transistor faulty internal parts broken LCD showing ERRL after switch on Load cell damaged Overload may cause the weigh to malfunction Software syst...

Page 37: ...36...